 +====== Setup Checklist ======
 +
 +==== Before Patient's Arrival ====
 +
 +{{:Checkbox.jpg}} **Turn on ALL systems**
 +
 +{{:Checkbox.jpg}} **Verify Position and Orientation of cameras**
 +
 +Verify the position and orientation of Motion Capture Cameras
 +Verify the position and orientation of Force Platforms
 +Verify the position and orientation of Force Structures
 +Verify the position and orientation of Obstacles or Environment objects
 +{{:Checkbox.jpg}} **Perform System Calibration**
 +
 +Perform static and/or dynamic calibrations of data collection devices
 +Verify results against the standards developed/referenced by your laboratory
 +{{:Checkbox.jpg}} **Verify the protocol being used for the session**
 +
 +Verify the experimental protocol for the current data collection session
 +{{:Checkbox.jpg}} **Set appropriate system settings**
 +
 +As per experimental protocol, set and verify system settings
 +e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc.
 +{{:Checkbox.jpg}} **Perform CalTester test**
 +
 +Perform Caltester test at a minimum of 2 locations on each force platform
 +Verify against prior laboratory results
 +{{:Checkbox.jpg}} **Prepare necessary markers and supplies**
 +
 +==== Patient's Arrival ====
 +
 +{{:Checkbox.jpg}} **Obtain informed consent**
 +
 +{{:Checkbox.jpg}} **Record subject details**
 +
 +Insure that there are no contraindications for the patient completing the data collection
 +This may include data collection done via questionnaires or measurements
 +If data collection includes patient questionnaires check to make sure that they have been completed correctly
 +{{:Checkbox.jpg}} **Apply markers/IMUs/EMGs as per experimental protocol**
 +
 +Take a set of digital pictures of the subject for post-hoc review of the marker placement.
 +{{:Checkbox.jpg}} **Record static calibration trial**
 +
 +Ensure all markers are visible
 +{{:Checkbox.jpg}} **Verify recorded marker set**
 +
 +Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol
 +{{:Checkbox.jpg}} **Remove anatomical markers**
 +
 +If necessary, remove anatomical markers not needed for tracking in motion trials
 +{{:Checkbox.jpg}} **Set the software system to broadcast the data**
 +
 +Each manufacturer has their own method of turning on the broadcasting option in their software
 +Check your software/hardware system's user's manual for more information
 +==== After Patient Leaves ====
 +
 +{{:Checkbox.jpg}} **Clean up work station**
 +
 +{{:Checkbox.jpg}} **Save data as appropriate**
 +
 +
  