User Tools

Site Tools


other:visual3dserver:tutorials:setup_checklist

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
other:visual3dserver:tutorials:setup_checklist [2024/07/16 19:23] – created sgrangerother:visual3dserver:tutorials:setup_checklist [2024/07/17 15:44] (current) – created sgranger
Line 1: Line 1:
-====== Setup_Checklist ======+====== Setup Checklist ======
  
 ==== Before Patient's Arrival ==== ==== Before Patient's Arrival ====
  
-{{Checkbox.jpg}} **Turn on ALL systems**+{{:Checkbox.jpg}} **Turn on ALL systems**
  
-{{Checkbox.jpg}} **Verify Position and Orientation of cameras**+{{:Checkbox.jpg}} **Verify Position and Orientation of cameras**
  
 Verify the position and orientation of Motion Capture Cameras Verify the position and orientation of Motion Capture Cameras
Line 11: Line 11:
 Verify the position and orientation of Force Structures Verify the position and orientation of Force Structures
 Verify the position and orientation of Obstacles or Environment objects Verify the position and orientation of Obstacles or Environment objects
-{{Checkbox.jpg}} **Perform System Calibration**+{{:Checkbox.jpg}} **Perform System Calibration**
  
 Perform static and/or dynamic calibrations of data collection devices Perform static and/or dynamic calibrations of data collection devices
 Verify results against the standards developed/referenced by your laboratory Verify results against the standards developed/referenced by your laboratory
-{{Checkbox.jpg}} **Verify the protocol being used for the session**+{{:Checkbox.jpg}} **Verify the protocol being used for the session**
  
 Verify the experimental protocol for the current data collection session Verify the experimental protocol for the current data collection session
-{{Checkbox.jpg}} **Set appropriate system settings**+{{:Checkbox.jpg}} **Set appropriate system settings**
  
 As per experimental protocol, set and verify system settings As per experimental protocol, set and verify system settings
 e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc. e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc.
-{{Checkbox.jpg}} **Perform CalTester test**+{{:Checkbox.jpg}} **Perform CalTester test**
  
 Perform Caltester test at a minimum of 2 locations on each force platform Perform Caltester test at a minimum of 2 locations on each force platform
 Verify against prior laboratory results Verify against prior laboratory results
-{{Checkbox.jpg}} **Prepare necessary markers and supplies**+{{:Checkbox.jpg}} **Prepare necessary markers and supplies**
  
 ==== Patient's Arrival ==== ==== Patient's Arrival ====
  
-{{Checkbox.jpg}} **Obtain informed consent**+{{:Checkbox.jpg}} **Obtain informed consent**
  
-{{Checkbox.jpg}} **Record subject details**+{{:Checkbox.jpg}} **Record subject details**
  
 Insure that there are no contraindications for the patient completing the data collection Insure that there are no contraindications for the patient completing the data collection
 This may include data collection done via questionnaires or measurements This may include data collection done via questionnaires or measurements
 If data collection includes patient questionnaires check to make sure that they have been completed correctly If data collection includes patient questionnaires check to make sure that they have been completed correctly
-{{Checkbox.jpg}} **Apply markers/IMUs/EMGs as per experimental protocol**+{{:Checkbox.jpg}} **Apply markers/IMUs/EMGs as per experimental protocol**
  
 Take a set of digital pictures of the subject for post-hoc review of the marker placement. Take a set of digital pictures of the subject for post-hoc review of the marker placement.
-{{Checkbox.jpg}} **Record static calibration trial**+{{:Checkbox.jpg}} **Record static calibration trial**
  
 Ensure all markers are visible Ensure all markers are visible
-{{Checkbox.jpg}} **Verify recorded marker set**+{{:Checkbox.jpg}} **Verify recorded marker set**
  
 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol
-{{Checkbox.jpg}} **Remove anatomical markers**+{{:Checkbox.jpg}} **Remove anatomical markers**
  
 If necessary, remove anatomical markers not needed for tracking in motion trials If necessary, remove anatomical markers not needed for tracking in motion trials
-{{Checkbox.jpg}} **Set the software system to broadcast the data**+{{:Checkbox.jpg}} **Set the software system to broadcast the data**
  
 Each manufacturer has their own method of turning on the broadcasting option in their software Each manufacturer has their own method of turning on the broadcasting option in their software
Line 55: Line 55:
 ==== After Patient Leaves ==== ==== After Patient Leaves ====
  
-{{Checkbox.jpg}} **Clean up work station**+{{:Checkbox.jpg}} **Clean up work station**
  
-{{Checkbox.jpg}} **Save data as appropriate**+{{:Checkbox.jpg}} **Save data as appropriate**
  
  
  
other/visual3dserver/tutorials/setup_checklist.1721157814.txt.gz · Last modified: 2024/07/16 19:23 by sgranger