+ | ====== Force Platforms Overview ====== | ||
+ | |||
+ | Note: This page addresses the representation of external forces and how these forces are included in the inverse dynamics calculations. If you are searching for the computation of Forces and Moments, see the section on [[Visual3D: | ||
+ | |||
+ | Force Platforms are commonly used for biomechanical analyses. So common that there is a fairly laissez-faire attitude towards force platform data. Many users don't realize the complexity of computing the ground reaction force vector in the laboratory coordinate system (where it is actually needed for Inverse Dynamics calculations), | ||
+ | |||
+ | ==== Verify Force Platform Parameters ==== | ||
+ | |||
+ | A common challenge for a manufacturer creating C3D formatted data files is the declaration of the Force Platform properties in the parameter section of the file. These parameters specify how the ANALOG signals stored in the C3D file should be transformed into the GRF, COFP, and FREEMOMENT signals by Visual3D. Before continuing with your analysis, ensure that your Force Platform parameters are correct. These parameters can be modified using the [[Visual3D: | ||
+ | |||
+ | ==== Calculating Force Signals ==== | ||
+ | |||
+ | Visual3D transforms force signals from the Force Platform' | ||
+ | |||
+ | The Ground Reaction Force is represented by 3 vectors: Force, Center of Pressure, and Free Moment. These Ground Reaction Force vectors are computed from the ANALOG signals recorded from the force platform, with the calculations performed as specified by the force platform manufacturer, | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ==== Filtering Force Signals ==== | ||
+ | |||
+ | On occasion it may be desirable to filter your force signals. There are two possible ways to achieve this, we recommend the former. | ||
+ | |||
+ | 1. Filter the ANALOG signals and select the option to use PROCESSED ANALOGS. In this case you will not need to filter the resulting FORCE, COFP, and FREEMOMENT signals. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | In order to use PROCESSED ANALOGS, verify in the settings menu that the option **Use Processed Anglogs for Ground Reaction Force Calculations** is checked. If this is the case, then Visual3D will calculate the FORCE, COFP, and FREEMOMENT signals using the signals found in ANALOG:: | ||
+ | |||
+ | 2. Filter the FORCE signals directly. In this case you should also filter the COFP and FREEMOMENT signals. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | In order to use these PROCESSED signals, verify in the settings menu that the option **Use Processed Targets for Model/ | ||
+ | |||
+ | ==== Minimum Force ==== | ||
+ | |||
+ | Visual3D' | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Applying a threshold value to the force signals ensures that If the computed force is less than the minimum force, then the FORCE and FREEMOMENT are set to zero, the COFP is set to [[Visual3D: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ==== Force Assignment ==== | ||
+ | |||
+ | In order to include a force in the Inverse Dynamics calculations it is necessary for the force to be assigned to a segment. Visual3D will attempt to assign the forces automatically, | ||
+ | |||
+ | Automatic force assignments are created based on the distance between the segment' | ||
+ | |||
+ | Using the View/Edit Segment to Force Assignments dialog, the user has the option of specifying a Custom Force. These custom forces must always be assigned manually. | ||
+ | |||
+ | ==== Force Structures ==== | ||
+ | |||
+ | In recent years force sensors have been included in a variety of structures, such as instrumented stairs and treadmills. Visual3D models these instruments as [[Visual3D: | ||
+ | |||
+ | ==== C3D Parameters ==== | ||
+ | |||
+ | If your data collection includes Force Platform data, then the C3D file's Parameters section contains information necessary for Visual3D to calculate the FORCE, COFP, and FREEMOMENT signals from the input ANALOG signals. These parameters include: | ||
+ | |||
+ | - [[Visual3D: | ||
+ | - [[Visual3D: | ||
+ | - [[Visual3D: | ||
+ | - [[Visual3D: | ||
+ | - [[Visual3D: | ||
+ | - [[Visual3D: | ||
+ | - [[Visual3D: | ||
+ | |||
+ | Force platform data is perhaps the most confusing aspect of the C3D file format. All of the force platform parameters required for the type of force platform being used must be defined correctly. Some of the parameters are specified by the Force Platform manufacturer; | ||
+ | |||
+ | **Important: | ||
+ | |||
+ | ==== C3D Channels ==== | ||
+ | |||
+ | The number of channels associated with a force platform and the information carried by each channel varies with the force platform manufacturer (usually represented as a force platform [[Visual3D: | ||
+ | |||
+ | | [[visual3d: | ||
+ | |||
+ | ==== Computing Force, COP, and Free Moment ==== | ||
+ | |||
+ | The force signals of interest for our kinetic analysis are the [[visual3d: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Although each force platform type records different information in its different channels, the process for converting the original recorded analog signals into the desired force signals follows the same common steps: | ||
+ | - Compute baselines | ||
+ | - Subtract baselines from original signals | ||
+ | - Pre-multiply by the calibration matrix (if applicable) | ||
+ | - Calculate the Ground Reaction Force | ||
+ | - Apply a threshold | ||
+ | - Transform data to the Laboratory Coordinate System | ||
+ | |||
+ | == Compute Baselines == | ||
+ | |||
+ | The [[Visual3D: | ||
+ | |||
+ | **Note:** most of the manufacturers arbitrarily set the range to be the first 10 frames of the trial. If the force platform is loaded during these first 10 frames, then **the ground reaction force signals will be incorrect**. If this is the case, then the user should either set the frames to 0,0 so that no baseline is subtracted, or should select frames in which the force platform is unloaded. | ||
+ | |||
+ | == Subtract Baselines == | ||
+ | |||
+ | The baseline value for each ANALOG channel represents the value of that channel' | ||
+ | |||
+ | < | ||
+ | [Tared Analog] = [Original Analog]-[Baseline] | ||
+ | </ | ||
+ | |||
+ | == Pre-multiply by the CalMatrix == | ||
+ | |||
+ | Several of the force platform types have a Calibration Matrix (Inverse Sensitivity Matrix) that is provided by the manufacturer. Visual3D pre-multiplies the values reported by the analog channels with this calibration matrix in order to convert the recorded analog signals from volts to the appropriate Force and/or Moment signal units. | ||
+ | |||
+ | For example, for a type 4 force platform: | ||
+ | < | ||
+ | [Converted Analog] = [Fx, Fy, Fz, Mx, My, Mz]= [CalMatrix][Tared Analog] | ||
+ | </ | ||
+ | |||
+ | **Note:** These signals are intermediate signals that are then used to compute the Ground Reaction Force. | ||
+ | |||
+ | == Calculate the Ground Reaction Force == | ||
+ | |||
+ | The Ground Reaction Force is represented by 3 vectors: Force, Centre of Pressure (COFP), and Free Moment. Each is calculated from the the appropriate analog signals. Different force platform types require different calculations for these Ground Reaction Force vectors. | ||
+ | |||
+ | For a Type 4 force platform, the force vector is equal to the intermediate force signals from the previous step. | ||
+ | |||
+ | < | ||
+ | Force[X] = Fx | ||
+ | Force[Y] = Fy | ||
+ | Force[Z] = Fz | ||
+ | </ | ||
+ | |||
+ | For a Type 4 force platform, the centre of pressure vector is computed as follows: | ||
+ | |||
+ | < | ||
+ | COP[X] = (ORIGIN[Z]*Force[X] - My) / Force[Z] | ||
+ | COP[Y] = (Mx + ORIGIN[Z]*Force[Y]) / Force[Z] | ||
+ | COP[Z] = ORIGIN[Z] | ||
+ | </ | ||
+ | |||
+ | **Note:** The [[Visual3D: | ||
+ | |||
+ | For a Type 4 force platform, the free moment vector is computed as follows: | ||
+ | |||
+ | < | ||
+ | FreeMoment[X] = 0 | ||
+ | FreeMoment[Y] = 0 | ||
+ | FreeMoment[Z] = Mz - ( COP[X]*Force[Y] - COP[Y]*Force[X] ) | ||
+ | </ | ||
+ | |||
+ | == Apply the Threshold == | ||
+ | |||
+ | The Visual3D Force Menu contains an option to set a [[Visual3D: | ||
+ | |||
+ | == Transform data to the Laboratory Coordinate System == | ||
+ | |||
+ | At this point the signals have been computed in the Force Platform Coordinate system and must be transformed into the Laboratory Coordinate System to give them meaning relative to the motion capture data. | ||
+ | |||
+ | As long as the force platform is accurately located within the lab, for example by using the [[caltester: | ||
+ | |||
+ | |||
+ | ==== Learn More ==== | ||
+ | |||
+ | Complete the Visual3D [[Visual3D: | ||
+ | |||
+ | |||