visual3d:documentation:modeling:marker_sets:pig_ll_original
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:modeling:marker_sets:pig_ll_original [2024/06/17 18:17] – created sgranger | visual3d:documentation:modeling:marker_sets:pig_ll_original [2024/07/17 15:45] (current) – created sgranger | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== PiG LL Original ====== | ||
\\ | \\ | ||
**N.B. While every effort has been made to ensure the correct implementation of the Plug-In Gait model in Visual3D, some differences may still persist, most likely caused by the different pose estimations used within Nexus and Visual3D. Please report any errors to support@c-motion.com.** | **N.B. While every effort has been made to ensure the correct implementation of the Plug-In Gait model in Visual3D, some differences may still persist, most likely caused by the different pose estimations used within Nexus and Visual3D. Please report any errors to support@c-motion.com.** | ||
- | ===== Introduction | + | ==== Introduction ==== |
The conventional gait model (CGM) has many variations and can go by many names: Helen Hayes, Vicon Clinical Manager, Newington, and Cleveland Clinic to name a few. We highly recommend reading the [[Visual3D: | The conventional gait model (CGM) has many variations and can go by many names: Helen Hayes, Vicon Clinical Manager, Newington, and Cleveland Clinic to name a few. We highly recommend reading the [[Visual3D: | ||
Line 12: | Line 12: | ||
In this tutorial, we describe this implementation of [[http:// | In this tutorial, we describe this implementation of [[http:// | ||
- | ===== Pose Estimation | + | ==== Pose Estimation ==== |
Plug-In Gait uses a Direct (Non-Optimal) Pose Estimation for computing the position and orientation of each segment based on a set of 3 tracking markers. | Plug-In Gait uses a Direct (Non-Optimal) Pose Estimation for computing the position and orientation of each segment based on a set of 3 tracking markers. | ||
Line 20: | Line 20: | ||
The results of the implementation of the Plug-In Gait model in Visual3D will differ slightly from the Vicon PIG implementation, | The results of the implementation of the Plug-In Gait model in Visual3D will differ slightly from the Vicon PIG implementation, | ||
- | ===== Conventional Gait Model Decisions | + | ==== Conventional Gait Model Decisions ==== |
Since there are variations of the conventional gait model, decisions must be made prior to marker placement and data collection. The diagram below lays out some of the decisions based on body segment. This is not comprehensive since many variations exist. The following sections describe the conventional gait model marker placement locations and challenges based on these options. | Since there are variations of the conventional gait model, decisions must be made prior to marker placement and data collection. The diagram below lays out some of the decisions based on body segment. This is not comprehensive since many variations exist. The following sections describe the conventional gait model marker placement locations and challenges based on these options. | ||
- | [[index.php? | + | {{: |
In the case of the Plug-In Gait, the decisions have already been made for option 2(c), 4(b) and 5(b). Using Visual3D, it is possible to opt for different model decisions if needed or relevant. This would however not be consistent with the Plug-In Gait's implementation per se. | In the case of the Plug-In Gait, the decisions have already been made for option 2(c), 4(b) and 5(b). Using Visual3D, it is possible to opt for different model decisions if needed or relevant. This would however not be consistent with the Plug-In Gait's implementation per se. | ||
- | ===== Anthropometric measures necessary for the Conventional Gait Model ===== | + | ==== Anthropometric measures necessary for the Conventional Gait Model ==== |
These lists describe the anthropometric measurements that are needed for the Plug-In Gait variations of the Clinical Gait Model. These are the anthropometric measurements also required in // | These lists describe the anthropometric measurements that are needed for the Plug-In Gait variations of the Clinical Gait Model. These are the anthropometric measurements also required in // | ||
Line 47: | Line 47: | ||
* ASIS to greater trochanter distance (Calculated from a regression equation: 0.1288*Leg Length-0.04856) | * ASIS to greater trochanter distance (Calculated from a regression equation: 0.1288*Leg Length-0.04856) | ||
- | ==== Segment Coordinate Systems | + | === Segment Coordinate Systems === |
The definitions of the segment coordinate systems are based on anatomical orientations and are consistent with many other versions of the conventional gait model. | The definitions of the segment coordinate systems are based on anatomical orientations and are consistent with many other versions of the conventional gait model. | ||
- | ===== Marker Placement | + | ==== Marker Placement ==== |
Appropriate marker placement for any model is critical. The motion system only measures the center of the marker so when placing markers on the subject, use the center of the marker as your guide and not the attached bases or wands. It is also good practice to use eyeliner pencil or pen to mark on the subject the locations of the markers. If a marker is knocked off or falls, it can easily be placed in the same location. But, one has to be very careful about replacing markers. When Segment Optimization or Global Optimization pose estimation algorithms are used, the missing marker should be replaced, then the standing trial should be collected again; simply replacing the marker is not usually sufficient. | Appropriate marker placement for any model is critical. The motion system only measures the center of the marker so when placing markers on the subject, use the center of the marker as your guide and not the attached bases or wands. It is also good practice to use eyeliner pencil or pen to mark on the subject the locations of the markers. If a marker is knocked off or falls, it can easily be placed in the same location. But, one has to be very careful about replacing markers. When Segment Optimization or Global Optimization pose estimation algorithms are used, the missing marker should be replaced, then the standing trial should be collected again; simply replacing the marker is not usually sufficient. | ||
- | ==== Marker Color Convention | + | === Marker Color Convention === |
The different colored circles relate to the different roles of the markers. | The different colored circles relate to the different roles of the markers. | ||
Line 61: | Line 61: | ||
**Red Markers** are used for both the segment definition and for tracking | **Red Markers** are used for both the segment definition and for tracking | ||
**Black markers** are virtual markers used for both the segment definition and for tracking | **Black markers** are virtual markers used for both the segment definition and for tracking | ||
- | ==== Pelvis Markers | + | === Pelvis Markers === |
The Plug-In Gait pelvis has two marker set variations: a three-marker marker set and a four-marker marker set. In Visual3D, both marker sets can be used with the [[Visual3D: | The Plug-In Gait pelvis has two marker set variations: a three-marker marker set and a four-marker marker set. In Visual3D, both marker sets can be used with the [[Visual3D: | ||
Line 69: | Line 69: | ||
The [[Visual3D: | The [[Visual3D: | ||
- | === Four Marker Set Pelvis | + | == Four Marker Set Pelvis == |
- | [[PelvisPiG4.png]] | + | {{:PelvisPiG4.png}} |
RIAS , LIAS= Right Ilium Anterior Superior (Anterior Superior Iliac Spine) | RIAS , LIAS= Right Ilium Anterior Superior (Anterior Superior Iliac Spine) | ||
RIPS , LIPS= Left Ilium Posterior Superior (Posterior Superior Iliac Spine) | RIPS , LIPS= Left Ilium Posterior Superior (Posterior Superior Iliac Spine) | ||
- | === Three Marker Set Pelvis | + | == Three Marker Set Pelvis == |
- | [[PelvisPiG3.png]] | + | {{:PelvisPiG3.png}} |
RIAS , LIAS= Right Ilium Anterior Superior (Anterior Superior Iliac Spine) | RIAS , LIAS= Right Ilium Anterior Superior (Anterior Superior Iliac Spine) | ||
Line 89: | Line 89: | ||
The origin of the pelvis is at the mid-point of the ASIS markers and perpendicular to the line joining them regardless of the position of the PSIS markers. Since this is the case, medial/ | The origin of the pelvis is at the mid-point of the ASIS markers and perpendicular to the line joining them regardless of the position of the PSIS markers. Since this is the case, medial/ | ||
- | === Placement challenges for obese subjects | + | == Placement challenges for obese subjects == |
Placement on obese subjects can be challenging due to excessive tissue. Have the subject stand to palpate the ASIS's since the skin and tissue may be in different locations for the prone and standing position. There are three options for marker placement: move the ASIS markers more lateral or move the ASIS markers anterior or use the pointer to identify a virtual point. | Placement on obese subjects can be challenging due to excessive tissue. Have the subject stand to palpate the ASIS's since the skin and tissue may be in different locations for the prone and standing position. There are three options for marker placement: move the ASIS markers more lateral or move the ASIS markers anterior or use the pointer to identify a virtual point. | ||
- | == Move ASIS markers Laterally | + | = Move ASIS markers Laterally = |
Move both ASIS markers lateral to the anatomical ASIS in the pelvic plane. Make sure that the lateral displacement is symmetrical between sides. Measure this distance and modify the **Subject Metric Inter-ASIS_distance**. | Move both ASIS markers lateral to the anatomical ASIS in the pelvic plane. Make sure that the lateral displacement is symmetrical between sides. Measure this distance and modify the **Subject Metric Inter-ASIS_distance**. | ||
- | == Move ASIS markers Anteriorly | + | = Move ASIS markers Anteriorly = |
Move both ASIS markers anterior (coming forward directly anterior to the landmarks so that they lie directly over them in the coronal plane of the pelvis) by an equal distance in relation to where they would have been. Measure this distance and add a landmark that specifies the actual location of the ASIS. These ASIS landmarks should be used for defining the segment coordinate system of the pelvis, but the original markers should be used as the tracking markers for the pelvis. | Move both ASIS markers anterior (coming forward directly anterior to the landmarks so that they lie directly over them in the coronal plane of the pelvis) by an equal distance in relation to where they would have been. Measure this distance and add a landmark that specifies the actual location of the ASIS. These ASIS landmarks should be used for defining the segment coordinate system of the pelvis, but the original markers should be used as the tracking markers for the pelvis. | ||
- | == Use a Pointer to make ASIS Landmarks | + | = Use a Pointer to make ASIS Landmarks = |
A [[Visual3D: | A [[Visual3D: | ||
- | ==== Upper Leg Markers | + | === Upper Leg Markers === |
- | [[ThighPiG.png]] | + | {{:ThighPiG.png}} |
RHJC, LHJC = Hip joint center | RHJC, LHJC = Hip joint center | ||
Line 115: | Line 115: | ||
- | There are two variations for the thigh segment. One in which a [[Knee_Alignment_Device|Knee Alignment Device]] (KAD) is used, one without a KAD. | + | There are two variations for the thigh segment. One in which a [[Visual3D: |
- | === Without Knee Alignment Device (KAD) === | + | == Without Knee Alignment Device (KAD) == |
The upper leg segment can be visualized as a triangle or plane formed by the Hip Joint Center (RIGH_HIP, LEFT_HIP), lateral thigh marker and lateral knee marker. Palpate lateral epicondyles to estimate the knee flexion/ | The upper leg segment can be visualized as a triangle or plane formed by the Hip Joint Center (RIGH_HIP, LEFT_HIP), lateral thigh marker and lateral knee marker. Palpate lateral epicondyles to estimate the knee flexion/ | ||
- | When not using a [[Knee_Alignment_Device|Knee Alignment Device]] (KAD) the placement of the thigh markers (RTHI, LTHI) or wands (stick on a base with an attached marker) is critical. This marker is used to define the frontal plane of the femur (knee flexion/ | + | When not using a [[Visual3D: |
- | === Using a Knee Alignment Device (KAD) === | + | == Using a Knee Alignment Device (KAD) == |
- | As above, the upper leg segment can be visualized as a triangle or plane formed by the Hip Joint Center (RIGHT_HIP, LEFT_HIP), lateral thigh marker and lateral knee marker. The difference in this variation is that a [[Knee_Alignment_Device|Knee Alignment Device]] (KAD) is used in the static trial to define the coronal plane for the knee. Palpate the lateral epicondyles to estimate the knee flexion/ | + | As above, the upper leg segment can be visualized as a triangle or plane formed by the Hip Joint Center (RIGHT_HIP, LEFT_HIP), lateral thigh marker and lateral knee marker. The difference in this variation is that a [[Visual3D: |
After the subject static calibration trial, remove the KAD and mark the KAD location on the lateral epicondyle with a eyeliner pencil or pen. Place a marker on that location (RKNE, LKNE). Placement of the thigh (RTHI, LTHI) markers or wands (stick on a base with an attached marker) is not critical in this case so it can be placed anywhere on the thigh. | After the subject static calibration trial, remove the KAD and mark the KAD location on the lateral epicondyle with a eyeliner pencil or pen. Place a marker on that location (RKNE, LKNE). Placement of the thigh (RTHI, LTHI) markers or wands (stick on a base with an attached marker) is not critical in this case so it can be placed anywhere on the thigh. | ||
- | == Improper Placement of KAD == | + | = Improper Placement of KAD = |
The KAD can be aligned improperly or can slip after placement. If this does occur, then the knee's frontal plane will be improperly defined. Care should be taken when using the KAD. As a safety measure, it may be best practice when using the KAD to align the thigh marker correctly or use medial knee markers (which is detailed in the next section) and collect a static trial with the KAD and one without the KAD. A choice can be made post data collection on whether to use the KAD alignment or the thigh or medial knee alignment. | The KAD can be aligned improperly or can slip after placement. If this does occur, then the knee's frontal plane will be improperly defined. Care should be taken when using the KAD. As a safety measure, it may be best practice when using the KAD to align the thigh marker correctly or use medial knee markers (which is detailed in the next section) and collect a static trial with the KAD and one without the KAD. A choice can be made post data collection on whether to use the KAD alignment or the thigh or medial knee alignment. | ||
- | === Knee Width === | + | == Knee Width == |
Because no medial knee marker is used, **it is critically important to measure the width of the knee** (e.g. the distance between the medial and lateral epicondyles) since this information is used to identify the distal end of the thigh segment, i.e the knee joint center. | Because no medial knee marker is used, **it is critically important to measure the width of the knee** (e.g. the distance between the medial and lateral epicondyles) since this information is used to identify the distal end of the thigh segment, i.e the knee joint center. | ||
- | ==== Lower Leg Markers | + | === Lower Leg Markers === |
- | [[ShankPiG.png]] | + | {{:ShankPiG.png}} |
RKJC, LKJC = Knee Joint Center | RKJC, LKJC = Knee Joint Center | ||
Line 148: | Line 148: | ||
As in the thigh, the placement of the shank markers (RSK, LSK) or wands (stick on a base with an attached marker) is critical. This marker is used to define the coronal plane of the tibia (ankle flexion/ | As in the thigh, the placement of the shank markers (RSK, LSK) or wands (stick on a base with an attached marker) is critical. This marker is used to define the coronal plane of the tibia (ankle flexion/ | ||
- | === Ankle Diameter | + | == Ankle Diameter == |
Because no medial ankle marker is used, it is **critically important** to measure the diameter of the ankle (e.g. the distance between the medial and lateral malleolus) since this information is used to identify the distal end of the shank segment. | Because no medial ankle marker is used, it is **critically important** to measure the diameter of the ankle (e.g. the distance between the medial and lateral malleolus) since this information is used to identify the distal end of the shank segment. | ||
- | ==== Foot Markers | + | === Foot Markers === |
The foot is visualized as a line along the long axis of the foot from the 2nd metatarsal heads and the ankle joint center projected onto the plantar surface of the foot. | The foot is visualized as a line along the long axis of the foot from the 2nd metatarsal heads and the ankle joint center projected onto the plantar surface of the foot. | ||
Line 163: | Line 163: | ||
See [[Visual3D: | See [[Visual3D: | ||
- | [[FootPiG.png]] | + | {{:FootPiG.png}} |
RAJC, LAJC = Ankle Joint Center | RAJC, LAJC = Ankle Joint Center | ||
RTOE, LTOE = Second metatarsal head | RTOE, LTOE = Second metatarsal head | ||
RHEE, LHEE = Center of Calcaneus | RHEE, LHEE = Center of Calcaneus | ||
- | ===== Create the Lower-Limb Plug-In Gait Model ===== | + | ==== Create the Lower-Limb Plug-In Gait Model ==== |
This section will detail the construction of the Plug-In Gait version of the Conventional Gait Model. Click [[[https:// | This section will detail the construction of the Plug-In Gait version of the Conventional Gait Model. Click [[[https:// | ||
Line 175: | Line 175: | ||
- From the **Model** menu, select **Create (Add Static Calibration File)**\\ | - From the **Model** menu, select **Create (Add Static Calibration File)**\\ | ||
- | [[tutorial1_2.jpg{{/ | + | {{:tutorial1_2.jpg}}\\ |
- Select **Hybrid Model from C3DFile** | - Select **Hybrid Model from C3DFile** | ||
Line 182: | Line 182: | ||
- Visual3D will switch to Model Building mode automatically. The 3D viewer will display the average value of the marker locations from the standing file. The dialog bar to the left of the screen will contain a list of segments, which by default will contain only a segment representing the Laboratory. | - Visual3D will switch to Model Building mode automatically. The 3D viewer will display the average value of the marker locations from the standing file. The dialog bar to the left of the screen will contain a list of segments, which by default will contain only a segment representing the Laboratory. | ||
- | ==== Pelvis | + | === Pelvis === |
- | [[PelvisPiG3.png]] | + | {{:PelvisPiG3.png}} |
- | [[PelvisPiG4.png]] | + | {{:PelvisPiG4.png}} |
RASI, LASI = Right Ilium Anterior Superior (Anterior Superior Iliac Spine) | RASI, LASI = Right Ilium Anterior Superior (Anterior Superior Iliac Spine) | ||
Line 200: | Line 200: | ||
- | === Creating the SCRM landmark | + | == Creating the SCRM landmark == |
If you have opted for the 4-marker pelvis marker set, where both right and left posterior superior iliac spines are identified, a sacrum landmark has to be created to define the pelvis segment. | If you have opted for the 4-marker pelvis marker set, where both right and left posterior superior iliac spines are identified, a sacrum landmark has to be created to define the pelvis segment. | ||
Line 214: | Line 214: | ||
AXIAL=0.5 | AXIAL=0.5 | ||
//Check Offset By Percent// | //Check Offset By Percent// | ||
- | === Creating the Pelvis Segment | + | == Creating the Pelvis Segment == |
- From the **Segment Name** box, select //Pelvis.// | - From the **Segment Name** box, select //Pelvis.// | ||
- From the **Segment Type** box, select //Coda.// | - From the **Segment Type** box, select //Coda.// | ||
- Click **Create.**\\ | - Click **Create.**\\ | ||
- | [[CODA_pelvis1.jpg]]\\ | + | {{:CODA_pelvis1.jpg}}\\ |
\\ | \\ | ||
- A dialogue box labeled **Enter Body Mass and Height** will open because Visual3D needs the subject to be assigned a mass and a height. For this example, Enter //75// kg and //1.76// m, and click **OK.**\\ | - A dialogue box labeled **Enter Body Mass and Height** will open because Visual3D needs the subject to be assigned a mass and a height. For this example, Enter //75// kg and //1.76// m, and click **OK.**\\ | ||
- | [[CODA_height_%26_weight.jpg]]\\ | + | {{:26_weight.jpg}}\\ |
\\ | \\ | ||
- A dialogue box labeled **CODA Segment Markers** will open. Select the markers so that they correspond to the figure below. Click **Close.**\\ | - A dialogue box labeled **CODA Segment Markers** will open. Select the markers so that they correspond to the figure below. Click **Close.**\\ | ||
**Note: as shown in the figure above, the SCRM marker (or Landmark) is used for both //R.PSIS// and // | **Note: as shown in the figure above, the SCRM marker (or Landmark) is used for both //R.PSIS// and // | ||
- | [[PiGPelvisMarkers.png]].\\ | + | {{:PiGPelvisMarkers.png}}.\\ |
\\ | \\ | ||
** | ** | ||
Line 236: | Line 236: | ||
**Note: Creating a Coda Pelvis in Visual3D automatically generates the RIGHT_HIP and LEFT_HIP landmarks. However, these landmarks should simply be ignored since a different definition will be used to compute the hip joint centres (see section below).** | **Note: Creating a Coda Pelvis in Visual3D automatically generates the RIGHT_HIP and LEFT_HIP landmarks. However, these landmarks should simply be ignored since a different definition will be used to compute the hip joint centres (see section below).** | ||
- | === Enter Subject Measurements | + | == Enter Subject Measurements == |
The Plug-In Gait conventional gait model requires measurement of leg length as well as knee and ankle width. To enter those measurements in Visual3D, a **Subject Data Metric** must be created for each measurement.\\ | The Plug-In Gait conventional gait model requires measurement of leg length as well as knee and ankle width. To enter those measurements in Visual3D, a **Subject Data Metric** must be created for each measurement.\\ | ||
**While these metrics are saved in the //Model Template// (.mdh) file, their values should be updated for each patient, to reflect patient specific measurements.** | **While these metrics are saved in the //Model Template// (.mdh) file, their values should be updated for each patient, to reflect patient specific measurements.** | ||
- | [[PiGRight_Leg_Length.png]] | + | {{:PiGRight_Leg_Length.png}} |
\\ | \\ | ||
Line 324: | Line 324: | ||
- Click on **OK** | - Click on **OK** | ||
- | ==== Hip Joint Center | + | === Hip Joint Center === |
The Hip Joint Center regression equation for the [[Visual3D: | The Hip Joint Center regression equation for the [[Visual3D: | ||
Line 356: | Line 356: | ||
- | === Metrics to compute Hip Joint Center | + | == Metrics to compute Hip Joint Center == |
In order to create the Hip Joint center landmarks in Visual3D using the above-mentioned equations, it is highly recommended to create separate metric entries for each equation parameter. This allows the user to identify transcription errors and typos more easily. As a precaution, make sure that a value is computed in the //Value// column of each defined metrics. A //No Data// return value means a mathematical error (missing * or parentheses for example). | In order to create the Hip Joint center landmarks in Visual3D using the above-mentioned equations, it is highly recommended to create separate metric entries for each equation parameter. This allows the user to identify transcription errors and typos more easily. As a precaution, make sure that a value is computed in the //Value// column of each defined metrics. A //No Data// return value means a mathematical error (missing * or parentheses for example). | ||
Line 438: | Line 438: | ||
- | === XYZ coordinates for the Hip Joint Center | + | == XYZ coordinates for the Hip Joint Center == |
**While defining/ | **While defining/ | ||
Line 496: | Line 496: | ||
- | === Creating the Hip Joint Center Landmarks | + | == Creating the Hip Joint Center Landmarks == |
Go to the **Landmarks** tab, and click on **Add New Landmark**: | Go to the **Landmarks** tab, and click on **Add New Landmark**: | ||
Line 525: | Line 525: | ||
//Do Not Check Offset By Percent// | //Do Not Check Offset By Percent// | ||
**Do Not Check Calibration Only Landmark** | **Do Not Check Calibration Only Landmark** | ||
- | ==== Thigh Segment | + | === Thigh Segment === |
- | [[ThighPiG.png]] | + | {{:ThighPiG.png}} |
RHJC, LHJC = Hip joint center | RHJC, LHJC = Hip joint center | ||
RTHI, LTHI = Lateral Thigh marker | RTHI, LTHI = Lateral Thigh marker | ||
RKNE, LKNE = Lateral Knee marker | RKNE, LKNE = Lateral Knee marker | ||
- | === Creating the Thigh Segment Without a Knee Alignment Device | + | == Creating the Thigh Segment Without a Knee Alignment Device == |
- | == Creating the Thigh Segments | + | = Creating the Thigh Segments = |
Once the Hip Joint Centers have been created, the thigh segments can now be defined. | Once the Hip Joint Centers have been created, the thigh segments can now be defined. | ||
- | [[PiGThigh.png]] | + | {{:PiGThigh.png}} |
From the **Segment Name** list, select //Right Thigh//\\ | From the **Segment Name** list, select //Right Thigh//\\ | ||
Line 564: | Line 564: | ||
- Click on **Build Model** | - Click on **Build Model** | ||
- | === Creating the Thigh Segment With a Knee Alignment Device | + | == Creating the Thigh Segment With a Knee Alignment Device == |
- | == Create KAD Segments | + | = Create KAD Segments = |
We must make a virtual segment (kinematic only) for the KAD. To create a //Kinematic Only// right KAD segment: | We must make a virtual segment (kinematic only) for the KAD. To create a //Kinematic Only// right KAD segment: | ||
Line 575: | Line 575: | ||
- Check the **Kinematic Only** box | - Check the **Kinematic Only** box | ||
- Click **Create.**\\ | - Click **Create.**\\ | ||
- | [[index.php? | + | {{: |
- A dialogue box labeled **Helen Hayes/ | - A dialogue box labeled **Helen Hayes/ | ||
- | [[index.php? | + | {{: |
- Click **Build Model** to build the segment. You should now see the KAD segment coordinate system on your standing model. If you do not see the KAD coordinate system after clicking **Build Model**, double check the values you entered in the last step.\\ | - Click **Build Model** to build the segment. You should now see the KAD segment coordinate system on your standing model. If you do not see the KAD coordinate system after clicking **Build Model**, double check the values you entered in the last step.\\ | ||
- | [[index.php? | + | {{: |
Line 597: | Line 597: | ||
**Note: Many laboratories have taken to replacing the 25 mm markers with smaller markers, in an erroneous assumption that it would be a good idea to have all markers used on the body and the KAD to be the same size. This actually introduces an error in the assumptions of how the KAD is used. If this is done, the user must be careful to accommodate this change to the original assumptions.** | **Note: Many laboratories have taken to replacing the 25 mm markers with smaller markers, in an erroneous assumption that it would be a good idea to have all markers used on the body and the KAD to be the same size. This actually introduces an error in the assumptions of how the KAD is used. If this is done, the user must be careful to accommodate this change to the original assumptions.** | ||
- | == Edit Subject Metrics and Landmarks | + | = Edit Subject Metrics and Landmarks = |
When the KAD segments are created, Visual 3D creates the Knee and Ankle width subject metrics from default values. These need to be edited to reflect the current subject. #Click on **Subject Data/ | When the KAD segments are created, Visual 3D creates the Knee and Ankle width subject metrics from default values. These need to be edited to reflect the current subject. #Click on **Subject Data/ | ||
Line 611: | Line 611: | ||
The Subject Data/ | The Subject Data/ | ||
- | [[index.php? | + | {{: |
- | == Create Thigh Segments | + | = Create Thigh Segments = |
To create the right thigh segment: | To create the right thigh segment: | ||
Line 632: | Line 632: | ||
You should now see a thigh segment on your standing model. If you do not see the thigh segment after clicking Build Model, double check the values you entered in the last step.\\ | You should now see a thigh segment on your standing model. If you do not see the thigh segment after clicking Build Model, double check the values you entered in the last step.\\ | ||
- | [[index.php? | + | {{: |
To create the left thigh segment: | To create the left thigh segment: | ||
Line 650: | Line 650: | ||
- Click on **Build Model** | - Click on **Build Model** | ||
- | [[index.php? | + | {{: |
- | ==== Shank Segment | + | === Shank Segment === |
- | [[ShankPiG.png]] | + | {{:ShankPiG.png}} |
RKJC, LKJC = Knee joint center | RKJC, LKJC = Knee joint center | ||
RTIB, LTIB = Lateral Shank marker | RTIB, LTIB = Lateral Shank marker | ||
RANK, LANK= Lateral Malleolus | RANK, LANK= Lateral Malleolus | ||
- | === Creating the Shank segments | + | == Creating the Shank segments == |
- | == Creating the Knee Joint Centers | + | = Creating the Knee Joint Centers = |
First the Knee Joint Centers need to be created: | First the Knee Joint Centers need to be created: | ||
- | [[PiG_RKJC.png]] | + | {{:PiG_RKJC.png}} |
In the Landmarks tab, click on **Add New Landmark**. | In the Landmarks tab, click on **Add New Landmark**. | ||
Line 685: | Line 685: | ||
Once the Knee Joint Centers have been created, the Shank segments can now be defined. | Once the Knee Joint Centers have been created, the Shank segments can now be defined. | ||
- | == Defining the Shank Segments | + | = Defining the Shank Segments = |
- | [[PiGShank.png]] | + | {{:PiGShank.png}} |
From the **Segment Name** list, select //Right Shank//\\ | From the **Segment Name** list, select //Right Shank//\\ | ||
Line 713: | Line 713: | ||
- Click on **Build Model** | - Click on **Build Model** | ||
- | ==== Foot Segments | + | === Foot Segments === |
- | [[FootPiG.png]] | + | {{:FootPiG.png}} |
RAJC, LAJC = Ankle Joint Center | RAJC, LAJC = Ankle Joint Center | ||
RTOE, LTOE = Second metatarsal head | RTOE, LTOE = Second metatarsal head | ||
RHEE, LHEE = Center of Calcaneus | RHEE, LHEE = Center of Calcaneus | ||
- | === Creating the Foot Segments | + | == Creating the Foot Segments == |
- | == Creating the Ankle Joint Centers | + | = Creating the Ankle Joint Centers = |
First the Ankle Joint Centers need to be created: | First the Ankle Joint Centers need to be created: | ||
- | [[PiG_RAJC.png]] | + | {{:PiG_RAJC.png}} |
In the Landmarks tab, click on **Add New Landmark**. | In the Landmarks tab, click on **Add New Landmark**. | ||
Line 746: | Line 746: | ||
Once the Ankle Joint Centers have been created, the Foot segments can now be defined. | Once the Ankle Joint Centers have been created, the Foot segments can now be defined. | ||
- | == Defining the Foot Segments | + | = Defining the Foot Segments = |
- | [[PiGFoot.png]] | + | {{:PiGFoot.png}} |
From the **Segment Name** list, select //Right Foot//\\ | From the **Segment Name** list, select //Right Foot//\\ | ||
Line 776: | Line 776: | ||
- | == Defining the Virtual Foot Segments | + | = Defining the Virtual Foot Segments = |
- | [[PiGVFoot.png]] | + | {{:PiGVFoot.png}} |
In the **Segment Name** list, enter //Right Virtual Foot//\\ | In the **Segment Name** list, enter //Right Virtual Foot//\\ | ||
Line 806: | Line 806: | ||
- Click on **Build Model** | - Click on **Build Model** | ||
- | == Rotate Local Coordinate System | + | = Rotate Local Coordinate System = |
Once the Virtual Foot Segment are created, their corresponding local coordinate system must be modified to be aligned with the other segment' | Once the Virtual Foot Segment are created, their corresponding local coordinate system must be modified to be aligned with the other segment' | ||
Line 825: | Line 825: | ||
- | [[PiGRotateRMF.png]] | + | {{:PiGRotateRMF.png}} |
- | ===== Export to Vicon Polygon | + | ==== Export to Vicon Polygon ==== |
- | ==== Verifying Force Assignments | + | === Verifying Force Assignments === |
[[Visual3D: | [[Visual3D: | ||
- | ==== Basic Signal Processing | + | === Basic Signal Processing === |
[[Visual3D: | [[Visual3D: | ||
- | ==== Computing Gait Events | + | === Computing Gait Events === |
[[Visual3D: | [[Visual3D: | ||
- | ==== Computing Joint Angles | + | === Computing Joint Angles === |
- | ==== Computing Joint Moments | + | === Computing Joint Moments === |
- | ==== Export the Polygon C3D file ==== | + | === Export the Polygon C3D file === |
- | ===== References | + | ==== References ==== |
**Bell AL, Pederson DR, and Brand RA** (1989) Prediction of hip joint center location from external landmarks. Human Movement Science. 8:3-16 | **Bell AL, Pederson DR, and Brand RA** (1989) Prediction of hip joint center location from external landmarks. Human Movement Science. 8:3-16 | ||
Line 862: | Line 862: | ||
\\ | \\ | ||
- | |||
- | |||
visual3d/documentation/modeling/marker_sets/pig_ll_original.1718648234.txt.gz · Last modified: 2024/06/17 18:17 by sgranger