User Tools

Site Tools


visual3d:documentation:modeling:segments:hip_joint_landmarks

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:documentation:modeling:segments:hip_joint_landmarks [2024/06/18 13:29] sgrangervisual3d:documentation:modeling:segments:hip_joint_landmarks [2024/07/17 15:45] (current) – created sgranger
Line 1: Line 1:
 +====== Hip Joint Landmarks ======
 +
 **Estimates for the Right and Left Hip Joint Center are represented as Landmarks relative to the CODA and V3D_Composite pelvis segment coordinate systems.** **Estimates for the Right and Left Hip Joint Center are represented as Landmarks relative to the CODA and V3D_Composite pelvis segment coordinate systems.**
  
Line 6: Line 8:
   - The only difference between the equations for the CODA and V3D_Composite pelvis segments is that there is an offset (0.5*RPV_Depth-Target_Radius_ASIS). This is because the origin of the V3D_Composite pelvis is 50% of pelvis depth compared to the CODA pelvis origin.   - The only difference between the equations for the CODA and V3D_Composite pelvis segments is that there is an offset (0.5*RPV_Depth-Target_Radius_ASIS). This is because the origin of the V3D_Composite pelvis is 50% of pelvis depth compared to the CODA pelvis origin.
  
-==== Model Metrics ====+=== Model Metrics ===
  
 You will see the following model metrics used in the equations below. These model metrics are automatically created when you create the CODA or V3D_Composite pelvis. You will see the following model metrics used in the equations below. These model metrics are automatically created when you create the CODA or V3D_Composite pelvis.
Line 16: Line 18:
 **NOTE:** RPV_Depth is included in the subject metrics starting in Version 5 and the Target_Radius_ASIS is included in the subject metrics starting in Version 6. **NOTE:** RPV_Depth is included in the subject metrics starting in Version 5 and the Target_Radius_ASIS is included in the subject metrics starting in Version 6.
 In previous versions, these metrics must be added manually In previous versions, these metrics must be added manually
-===== Bell and Brand Hip Joint =====+==== Bell and Brand Hip Joint ====
  
 When you create the CODA or V3D_Composite pelvis, the hip joint landmarks are automatically created using the Bell and Brand regression equations. When you create the CODA or V3D_Composite pelvis, the hip joint landmarks are automatically created using the Bell and Brand regression equations.
Line 41: Line 43:
 **Note that in the 1990 article the ML distance is listed as 0.14 instead of 0.36 as used by Visual3D. The confusion lies in the location of the origin of the pelvis used in the article. Visual3D uses the mid-point of the ASIS, the article uses the Right ASIS location.** **Note that in the 1990 article the ML distance is listed as 0.14 instead of 0.36 as used by Visual3D. The confusion lies in the location of the origin of the pelvis used in the article. Visual3D uses the mid-point of the ASIS, the article uses the Right ASIS location.**
  
-{{BB90.jpg{{/images/2/29/BB90.jpg?290x271}}]] BB90a.jpg}}+{{:BB90.jpg}} {{:BB90a.jpg}}
  
-===== Harrington Hip Joint =====+==== Harrington Hip Joint ====
  
 //Harrington provided two regression equations for the hip joint landmark// //Harrington provided two regression equations for the hip joint landmark//
Line 49: Line 51:
   * Since the pelvis depth is defined differently between the CODA and V3D_Composite pelvis, use the set of equations which corresponds to the pelvis type you are using.   * Since the pelvis depth is defined differently between the CODA and V3D_Composite pelvis, use the set of equations which corresponds to the pelvis type you are using.
  
-==== Harrington 1 ====+=== Harrington 1 ===
  
 |Harrington Equation 1 |                            |                                                                   || |Harrington Equation 1 |                            |                                                                   ||
Line 62: Line 64:
 |Axial                 |-0.30*ASIS_Distance - 0.0109|-0.30*ASIS_Distance - 0.0109                                       || |Axial                 |-0.30*ASIS_Distance - 0.0109|-0.30*ASIS_Distance - 0.0109                                       ||
  
-==== Harrington 2 ====+=== Harrington 2 ===
  
 |Harrington Equation 2 |                                              |                                                                   || |Harrington Equation 2 |                                              |                                                                   ||
Line 80: Line 82:
 **Harrington ME, Zavatsky AB, Lawson SE, Yuan Z, Theologis TN.**(2007) Prediction of the hip joint centre in adults, children, and patients with cerebral palsy based on magnetic resonance imaging. **Harrington ME, Zavatsky AB, Lawson SE, Yuan Z, Theologis TN.**(2007) Prediction of the hip joint centre in adults, children, and patients with cerebral palsy based on magnetic resonance imaging.
 J Biomech. 2007;40(3):595-602. Epub 2006 Apr 3. J Biomech. 2007;40(3):595-602. Epub 2006 Apr 3.
-===== Davis Hip Joint =====+==== Davis Hip Joint ====
  
 If no clinical measurements are taken, the following values are calculated: If no clinical measurements are taken, the following values are calculated:
visual3d/documentation/modeling/segments/hip_joint_landmarks.1718717351.txt.gz · Last modified: 2024/06/18 13:29 by sgranger