User Tools

Site Tools


visual3d:documentation:modeling:segments:v3d_composite_pelvis

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
visual3d:documentation:modeling:segments:v3d_composite_pelvis [2024/06/14 17:24] – created sgrangervisual3d:documentation:modeling:segments:v3d_composite_pelvis [2024/07/17 15:45] (current) – created sgranger
Line 1: Line 1:
-|**Language:**|** English**  • [[index.php?title=V3D_Composite_Pelvis/fr&action=edit&redlink=1|français]] • [[index.php?title=V3D_Composite_Pelvis/it&action=edit&redlink=1|italiano]] • [[index.php?title=V3D_Composite_Pelvis/pt&action=edit&redlink=1|português]] • [[index.php?title=V3D_Composite_Pelvis/es&action=edit&redlink=1|español]] ****|+====== V3D Composite Pelvis ======
  
-|===== Contents =====\\ \\ \\ \\ * [[#Pelvis_Origin|1 Pelvis Origin]]\\ * [[#Pelvis_Orientation|2 Pelvis Orientation]]\\ * [[#Hip_Joint_Landmarks|3 Hip Joint Landmarks]]\\ * [[#Specifying_the_ASIS_distance|4 Specifying the ASIS distance]]| +|{{:V3D_Composite_wiki.png}}|The V3D_Composite pelvis refers to a pelvis segment created by C-Motion which is a variation on the [[Visual3D:Documentation:Modeling:Segments:Coda_Pelvis|Coda Pelvis]]. The pelvis segment is defined using the anatomical locations of the ASIS (Anterior Superior Iliac Spine) and the PSIS (Posterior Superior Iliac Spine). These landmarks are bony protuberances on the Pelvis bones that can be palpated on most (but not all) subjects. They are particularly useful if the subject is very thin, a cadaver, or a skeleton, and historically have been the reference points for defining the segment coordinate system for many experimental studies focused on determining regression equations for locating the hip joint centers. **Unfortunately, these landmarks are not easily palpated, or more importantly, cannot have motion capture markers placed accurately on them, for overweight subjects.**|
- +
-|[[File:V3D_Composite_wiki.png|{{/images/5/52/V3D_Composite_wiki.png?415x391}}]]|The V3D_Composite pelvis refers to a pelvis segment created by C-Motion which is a variation on the [[Visual3D:Documentation:Modeling:Segments:Coda_Pelvis|Coda Pelvis]]. The pelvis segment is defined using the anatomical locations of the ASIS (Anterior Superior Iliac Spine) and the PSIS (Posterior Superior Iliac Spine). These landmarks are bony protuberances on the Pelvis bones that can be palpated on most (but not all) subjects. They are particularly useful if the subject is very thin, a cadaver, or a skeleton, and historically have been the reference points for defining the segment coordinate system for many experimental studies focused on determining regression equations for locating the hip joint centers. **Unfortunately, these landmarks are not easily palpated, or more importantly, cannot have motion capture markers placed accurately on them, for overweight subjects.**|+
  
 \\ \\
Line 10: Line 8:
 **This pelvis was implemented in Visual3Dv5.02.17. CMO's which use this pelvis, cannot be opened in earlier versions of Visual3D.** **This pelvis was implemented in Visual3Dv5.02.17. CMO's which use this pelvis, cannot be opened in earlier versions of Visual3D.**
  
-===== Pelvis Origin =====+==== Pelvis Origin ====
  
 The Origin of the pelvis segment coordinate system is defined as the mid-point between the mid-ASIS and the mid-PSIS. The length of the V3D_Composite pelvis is equal to the segment depth. By defining the Origin and length of the V3D_Composite in this manner the Center of Mass of the V3D_Composite pelvis will be more representative of the true pelvis center of mass. This is particular useful when computing the total body center of mass, total body moment of inertia and the total body angular momentum. The Origin of the pelvis segment coordinate system is defined as the mid-point between the mid-ASIS and the mid-PSIS. The length of the V3D_Composite pelvis is equal to the segment depth. By defining the Origin and length of the V3D_Composite in this manner the Center of Mass of the V3D_Composite pelvis will be more representative of the true pelvis center of mass. This is particular useful when computing the total body center of mass, total body moment of inertia and the total body angular momentum.
  
-===== Pelvis Orientation =====+==== Pelvis Orientation ====
  
 The pelvis orientation is identical to the orientation of the CODA pelvis - the only difference between the two segments is the location of the origin. The pelvis orientation is identical to the orientation of the CODA pelvis - the only difference between the two segments is the location of the origin.
Line 29: Line 27:
 If the markers have been placed accurately, the pelvis segment coordinate system will typically be tilted forward about 20 degrees, which is unfortunate for the calculation of the hip angle, but can be resolved using virtual segments ([[Visual3D:Documentation:Modeling:Segments:Normalizing_the_Pelvis_Segment_Angle_Example|see Segment Examples 5]]). If the markers have been placed accurately, the pelvis segment coordinate system will typically be tilted forward about 20 degrees, which is unfortunate for the calculation of the hip angle, but can be resolved using virtual segments ([[Visual3D:Documentation:Modeling:Segments:Normalizing_the_Pelvis_Segment_Angle_Example|see Segment Examples 5]]).
  
-===== Hip Joint Landmarks =====+==== Hip Joint Landmarks ====
  
 Estimates for the Right and Left Hip Joint Center are represented as Landmarks that are created automatically when the V3D_Composite pelvis segment is created. The location of the landmark is defined as:\\ Estimates for the Right and Left Hip Joint Center are represented as Landmarks that are created automatically when the V3D_Composite pelvis segment is created. The location of the landmark is defined as:\\
Line 47: Line 45:
  
  
-===== Specifying the ASIS distance =====+==== Specifying the ASIS distance ====
  
 For some subjects the ASIS markers may be difficult to place precisely on the ASIS, so they get placed laterally. For some subjects the ASIS markers may be difficult to place precisely on the ASIS, so they get placed laterally.
Line 53: Line 51:
 This results in an ASIS distance that is too big, and this directly affects the location of the Hip Landmark. This results in an ASIS distance that is too big, and this directly affects the location of the Hip Landmark.
  
-The ASIS distance is a [[Model_Metrics_|Model Metric]] value that can be modified.+The ASIS distance is a [[Visual3D:Documentation:Modeling:Model_Metrics_|Model Metric]] value that can be modified.
  
 Switch to the Model Metrics Tab: Switch to the Model Metrics Tab:
  
-[[File:ModelMetricsDlg.jpg|{{/images/1/12/ModelMetricsDlg.jpg?409x449}}]]+{{:ModelMetricsDlg.jpg}}
  
 Select the ASIS_Distance item and select the Modify button Select the ASIS_Distance item and select the Modify button
  
-[[File:ASISDistance1.png|{{/images/c/ca/ASISDistance1.png?581x334}}]]+{{:ASISDistance1.png}}
  
 Enter the measured value of the ASIS distance. Enter the measured value of the ASIS distance.
  
-[[File:ASISDistance2.png|{{/images/2/2d/ASISDistance2.png?581x334}}]]+{{:ASISDistance2.png}}
  
 The hip landmark will be based on this ASIS distance. The hip landmark will be based on this ASIS distance.
  
- 
-Retrieved from "" 
  
  
visual3d/documentation/modeling/segments/v3d_composite_pelvis.1718385899.txt.gz · Last modified: 2024/06/14 17:24 by sgranger