Previous revision
visual3d:documentation:modeling:segments:v3d_composite_pelvis [2024/06/26 20:24] – created sgrangervisual3d:documentation:modeling:segments:v3d_composite_pelvis [2024/07/17 15:45] (current) – created sgranger
Line 1: Line 1:
-====== V3D_Composite_Pelvis ======+====== V3D Composite Pelvis ======
  
-|{{V3D_Composite_wiki.png}}|The V3D_Composite pelvis refers to a pelvis segment created by C-Motion which is a variation on the [[Visual3D:Documentation:Modeling:Segments:Coda_Pelvis|Coda Pelvis]]. The pelvis segment is defined using the anatomical locations of the ASIS (Anterior Superior Iliac Spine) and the PSIS (Posterior Superior Iliac Spine). These landmarks are bony protuberances on the Pelvis bones that can be palpated on most (but not all) subjects. They are particularly useful if the subject is very thin, a cadaver, or a skeleton, and historically have been the reference points for defining the segment coordinate system for many experimental studies focused on determining regression equations for locating the hip joint centers. **Unfortunately, these landmarks are not easily palpated, or more importantly, cannot have motion capture markers placed accurately on them, for overweight subjects.**|+|{{:V3D_Composite_wiki.png}}|The V3D_Composite pelvis refers to a pelvis segment created by C-Motion which is a variation on the [[Visual3D:Documentation:Modeling:Segments:Coda_Pelvis|Coda Pelvis]]. The pelvis segment is defined using the anatomical locations of the ASIS (Anterior Superior Iliac Spine) and the PSIS (Posterior Superior Iliac Spine). These landmarks are bony protuberances on the Pelvis bones that can be palpated on most (but not all) subjects. They are particularly useful if the subject is very thin, a cadaver, or a skeleton, and historically have been the reference points for defining the segment coordinate system for many experimental studies focused on determining regression equations for locating the hip joint centers. **Unfortunately, these landmarks are not easily palpated, or more importantly, cannot have motion capture markers placed accurately on them, for overweight subjects.**|
  
 \\ \\
Line 51: Line 51:
 This results in an ASIS distance that is too big, and this directly affects the location of the Hip Landmark. This results in an ASIS distance that is too big, and this directly affects the location of the Hip Landmark.
  
-The ASIS distance is a [[Model_Metrics_|Model Metric]] value that can be modified.+The ASIS distance is a [[Visual3D:Documentation:Modeling:Model_Metrics_|Model Metric]] value that can be modified.
  
 Switch to the Model Metrics Tab: Switch to the Model Metrics Tab:
  
-{{ModelMetricsDlg.jpg}}+{{:ModelMetricsDlg.jpg}}
  
 Select the ASIS_Distance item and select the Modify button Select the ASIS_Distance item and select the Modify button
  
-{{ASISDistance1.png}}+{{:ASISDistance1.png}}
  
 Enter the measured value of the ASIS distance. Enter the measured value of the ASIS distance.
  
-{{ASISDistance2.png}}+{{:ASISDistance2.png}}
  
 The hip landmark will be based on this ASIS distance. The hip landmark will be based on this ASIS distance.