visual3d:documentation:modeling:segments:v3d_composite_pelvis
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:modeling:segments:v3d_composite_pelvis [2024/07/17 15:10] – sgranger | visual3d:documentation:modeling:segments:v3d_composite_pelvis [2025/04/14 15:58] (current) – wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== | + | ====== |
+ | The V3D_Composite pelvis refers to a pelvis segment created by C-Motion which is a variation on the [[Visual3D: | ||
+ | {{: | ||
- | |{{: | + | **Note that this pelvis was implemented in Visual3Dv5.02.17. CMO/CMZ's which use this pelvis, cannot be opened in earlier versions of Visual3D.** |
- | + | ||
- | \\ | + | |
- | + | ||
- | + | ||
- | **This | + | |
==== Pelvis Origin ==== | ==== Pelvis Origin ==== | ||
Line 19: | Line 16: | ||
**Note that the midpoint of the PSIS markers is the same point as the SACRUM marker used for the Helen Hayes pelvis. Therefore, if a Helen Hayes markers set was used for the motion capture, a V3D_Composite pelvis can be created using the SACRUM marker twice (once for the left PSIS and once for the right PSIS).** | **Note that the midpoint of the PSIS markers is the same point as the SACRUM marker used for the Helen Hayes pelvis. Therefore, if a Helen Hayes markers set was used for the motion capture, a V3D_Composite pelvis can be created using the SACRUM marker twice (once for the left PSIS and once for the right PSIS).** | ||
+ | |||
The x-axis is defined from the Left ASIS towards the Right ASIS. | The x-axis is defined from the Left ASIS towards the Right ASIS. | ||
Line 29: | Line 27: | ||
==== Hip Joint Landmarks ==== | ==== Hip Joint Landmarks ==== | ||
- | Estimates for the Right and Left Hip Joint Center are represented as Landmarks that are created automatically when the V3D_Composite pelvis segment is created. The location of the landmark is defined as:\\ | + | Estimates for the Right and Left Hip Joint Center are represented as Landmarks that are created automatically when the V3D_Composite pelvis segment is created.\\ |
- | RHJC=(0.36*ASIS_Distance, | + | The location of the landmark is defined as:\\ |
- | LHJC=(0.36*ASIS_Distance, | + | |
+ | | ||
- | These estimates are adapted from the articles | + | These estimates are adapted from the articles: |
- | **Bell AL, Pederson DR, and Brand RA** (1989) Prediction of hip joint center location from external landmarks. Human Movement Science. 8:3-16:\\ | + | * **Bell AL, Pederson DR, and Brand RA** (1989) Prediction of hip joint center location from external landmarks. Human Movement Science. 8:3-16:\\ |
- | **Bell AL, Pedersen DR, Brand RA** (1990) A Comparison of the Accuracy of Several hip Center Location Prediction Methods. J Biomech. 23, 617-621.\\ | + | |
visual3d/documentation/modeling/segments/v3d_composite_pelvis.1721229043.txt.gz · Last modified: 2024/07/17 15:10 by sgranger