visual3d:documentation:modeling:segments:v3d_composite_pelvis
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:modeling:segments:v3d_composite_pelvis [2025/04/14 15:56] – wikisysop | visual3d:documentation:modeling:segments:v3d_composite_pelvis [2025/04/14 15:58] (current) – wikisysop | ||
---|---|---|---|
Line 3: | Line 3: | ||
{{: | {{: | ||
- | **This pelvis was implemented in Visual3Dv5.02.17. CMO/ | + | **Note that this pelvis was implemented in Visual3Dv5.02.17. CMO/ |
==== Pelvis Origin ==== | ==== Pelvis Origin ==== | ||
Line 27: | Line 27: | ||
==== Hip Joint Landmarks ==== | ==== Hip Joint Landmarks ==== | ||
- | Estimates for the Right and Left Hip Joint Center are represented as Landmarks that are created automatically when the V3D_Composite pelvis segment is created. The location of the landmark is defined as:\\ | + | Estimates for the Right and Left Hip Joint Center are represented as Landmarks that are created automatically when the V3D_Composite pelvis segment is created.\\ |
- | RHJC=(0.36*ASIS_Distance, | + | The location of the landmark is defined as:\\ |
- | LHJC=(0.36*ASIS_Distance, | + | |
+ | | ||
- | These estimates are adapted from the articles | + | These estimates are adapted from the articles: |
- | **Bell AL, Pederson DR, and Brand RA** (1989) Prediction of hip joint center location from external landmarks. Human Movement Science. 8:3-16:\\ | + | * **Bell AL, Pederson DR, and Brand RA** (1989) Prediction of hip joint center location from external landmarks. Human Movement Science. 8:3-16:\\ |
- | **Bell AL, Pedersen DR, Brand RA** (1990) A Comparison of the Accuracy of Several hip Center Location Prediction Methods. J Biomech. 23, 617-621.\\ | + | |
visual3d/documentation/modeling/segments/v3d_composite_pelvis.1744646197.txt.gz · Last modified: 2025/04/14 15:56 by wikisysop