visual3d:documentation:pipeline:file_commands:file_management_overview
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:pipeline:file_commands:file_management_overview [2024/06/17 17:06] – removed sgranger | visual3d:documentation:pipeline:file_commands:file_management_overview [2025/04/15 11:12] (current) – [File Management Overview] wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ===== File Management Overview ===== | ||
+ | |||
+ | File Commands are separated into three categories: | ||
+ | 1) File_Management\\ | ||
+ | 2) [[Visual3D: | ||
+ | 3) [[Visual3D: | ||
+ | |||
+ | |||
+ | \\ | ||
+ | For more pipeline commands, please see the [[Visual3D: | ||
+ | |||
+ | |||
+ | ---- | ||
+ | |||
+ | File Management commands are " | ||
+ | |||
+ | === File_Management === | ||
+ | |||
+ | ==== Exit_Workspace ==== | ||
+ | |||
+ | Exits Visual3D. This is useful when an external program launches Visual3D with a pipeline. When the pipeline is finished executing, Visual3D is closed. | ||
+ | ==== Recalc ==== | ||
+ | |||
+ | Recalculate the link model, event dependencies, | ||
+ | ==== Clear_Recalc_Pipeline ==== | ||
+ | |||
+ | ==== Select_Active_File ==== | ||
+ | |||
+ | Many of the pipeline commands in Visual3D act on the active files only, and only active file is animated in the 3D viewer. | ||
+ | ==== File_Close ==== | ||
+ | |||
+ | ==== File_New ==== | ||
+ | |||
+ | Clears the Workspace. Removes all models, motion trials, and the Global Workspace. | ||
+ | ==== File_Rename ==== | ||
+ | |||
+ | ==== Assign_Tags_To_File ==== | ||
+ | |||
+ | Files can be associated with other files opened in the Visual3D workspace by assigning a TAG to the file. | ||
+ | ==== Combine_Tags ==== | ||
+ | |||
+ | Use boolean logic to combine TAGS into a new TAG. | ||
+ | ==== Remove_Tags ==== | ||
+ | |||
+ | Removes the specified files from the TAG. Select ALL_FILES, a TAG, or a movement trial. | ||
+ | ==== Remove_CMO_History ==== | ||
+ | |||
+ | ==== Load_CMO_Library ==== | ||
+ | |||
+ | ==== Unload_CMO_Library ==== | ||
+ | |||
+ | ==== Copy_Point_Descriptions_To_Analog_Labels ==== | ||
+ | |||
+ | [[visual3d: | ||
+ | |||
+ | ==== Copy_Point_Descriptions_To_Point_Labels ==== | ||
+ | |||
+ | [[visual3d: | ||
+ | |||
+ | Motion Analysis Corporation exports C3D files that are consistent with an early version of the C3D file format. One of the restrictions in the early format was that POINT LABELS (e.g. names of the markers) were allowed to have only 4 characters. This command will cause Visual3D to copy the marker DESCRIPTION PARAMETER into the marker LABEL PARAMETER thus giving markers their long names. | ||
+ | = Create_Targets_For_LinkModelBased_Rotations = | ||
+ | |||
+ | = Create_Targets_For_LinkModelBased_Rotations_From_Velocity = | ||
+ | |||
+ | = Joint_Rotations_From_PSU_IMU = | ||
+ | |||
+ | = Fix_MAC_Eva7_C3DFile = | ||
+ | |||
+ | Visual3D does not act as a general C3D editor. Several commands, however, exist to edit specific parameters in the C3D file: | ||
+ | = Modify_Analog_Parameters = | ||
+ | |||
+ | = Modify_C3D_Manufacturer = | ||
+ | |||
+ | = Modify_Point_Parameters = | ||
+ | |||
+ | = Modify_C3D_Subjects_Parameters = | ||
+ | |||
+ | Modify the SUBJECT parameter group | ||
+ | = Modify_Point_Rate = | ||
+ | |||
+ | Modify the point and/or analog rate in the c3d file | ||
+ | = Remove_Prefix_From_Point_Labels = | ||
+ | |||
+ | Vicon Corporation' | ||
+ | = Upsample_Point_Data_To_Analog_Rate = | ||
+ | |||
+ | Not Available In Visual3Dv5: | ||
+ | = Modify_C3D_Trial_Parameters = | ||
+ | |||
+ | Modify the TRIAL parameter group | ||
+ | == Create_Text_Data == | ||
+ | |||
+ | Create a signal containing **Text** instead of a number | ||
+ | |||