+ | ====== Metric Frames Between Events ====== | ||
+ | |||
+ | ====Overview==== | ||
+ | The **Metric Frames Between Events** computes the number of frames between events (or start and end of a sequence of events) as a metric. This can be useful in determining time between events when frame rate is known. The **Metric Event Count** command can be found in the **Pipeline Workshop** under the **Metric** folder. | ||
+ | |||
+ | **Note that the frames will be at the POINT RATE because Visual3D computes Events at POINT RATE.** | ||
+ | |||
+ | ====Pipeline Command==== | ||
+ | |||
+ | The command can be found in the workshop as so: | ||
+ | |||
+ | < | ||
+ | Metric_Frames_Between_Events | ||
+ | ! / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ! / | ||
+ | ; | ||
+ | </ | ||
+ | |||
+ | ====Command Parameters==== | ||
+ | |||
+ | The following table shows the command parameters seen above and their descriptions: | ||
+ | |||
+ | |**RESULT_METRIC_FOLDER**|**The name of the result signal folder**| | ||
+ | |**RESULT_METRIC_NAME**|**The name of the result signal**| | ||
+ | |**EVENT_SEQUENCE**|** A list of events (separated by " | ||
+ | |**EXCLUDE_EVENTS**|**This Event Sequence must not be during the sequence requested. For example, LTO_RHS**| | ||
+ | |**GENERATE_MEAN_AND_STDDEV**|**(True or False)Generate the mean and standard deviation for all of the metrics created**| | ||
+ | |**APPEND_TO_EXISTING_VALUES**|**(True or False)Append this list of metrics to an existing metric of the same result name**| | ||
+ | |||
+ | ====Dialog==== | ||
+ | |||
+ | The command can be edited in a text editor or in a dialog form. To edit in the dialog pop up form either click on the **Edit** button in the pipeline workshop or double-click on the pipeline command. The dialog is shown below. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | |||
+ | The dialog box allows you to assign values to the command parameters outlined above. | ||
+ | |||
+ | ===== Example ===== | ||
+ | |||
+ | \\ | ||
+ | |||
+ | |||
+ | |< | ||
+ | |||
+ | ==== Visual3D Versions supporting Subject Prefixes ==== | ||
+ | |||
+ | NOTE: When using events in a command, the commands will iterate across subjects contained in the current workspace. As such, events and sequences listed as command parameters should NOT contain a prefix. As each subject is processed, the event range/ | ||
+ | |||
+ | |||
visual3d/documentation/pipeline/metric_commands/metric_frames_between_events.1720791009.txt.gz · Last modified: 2024/07/12 13:30 by sgranger