visual3d:documentation:pipeline:metric_commands:metric_signal_values_in_sequence
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:pipeline:metric_commands:metric_signal_values_in_sequence [2024/07/16 19:30] – created sgranger | visual3d:documentation:pipeline:metric_commands:metric_signal_values_in_sequence [2025/09/18 20:21] (current) – [Command Parameters] wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== | + | ====== |
- | **Get the values | + | ====Overview==== |
- | \\ | + | The metric command **Signal Values in Sequence** can be used to compute |
- | **Frames type:**\\ | + | |
- | 1 - Point Frames\\ | + | |
- | 2 - Data Frames\\ | + | |
- | 3 - Interpolate\\ | + | |
- | \\ | + | |
+ | ====Pipeline Command==== | ||
+ | The syntax for the function is as follows: | ||
< | < | ||
Metric_Signal_Values_In_Sequence | Metric_Signal_Values_In_Sequence | ||
- | / | ||
! / | ! / | ||
+ | / | ||
/ | / | ||
! / | ! / | ||
! / | ! / | ||
! / | ! / | ||
+ | ! / | ||
! / | ! / | ||
! / | ! / | ||
Line 23: | Line 21: | ||
! / | ! / | ||
! / | ! / | ||
- | ! / | ||
! / | ! / | ||
; | ; | ||
</ | </ | ||
- | \\ | + | ====Command Parameters==== |
+ | |||
+ | The following table shows the command parameters seen above and their descriptions: | ||
+ | |||
+ | |**RESULT_METRIC_FOLDER**|**The name of the result signal folder**| | ||
+ | |**RESULT_METRIC_NAME**|**The name of the result signal**| | ||
+ | |**EXPRESSION**|****| | ||
+ | |**PERCENT_LIST**|**A percentage offset relative to each event in the defined sequence**| | ||
+ | |**TIME_OFFSET_LIST**|**A time offset relative to each event in the defined sequence**| | ||
+ | |**FRAME_OFFSET_LIST**|**A frame offset relative to each event in the defined sequence**| | ||
+ | |**EVENT_LIST**|****| | ||
+ | |**USE_FRAMES_TYPE**|****| | ||
+ | |**SEQUENCE_INSTANCE**|****| | ||
+ | |**EVENT_SEQUENCE**|** A list of events (separated by " | ||
+ | |**EXCLUDE_EVENTS**|**This Event Sequence must not be during the sequence requested. For example, LTO_RHS**| | ||
+ | |**GENERATE_MEAN_AND_STDDEV**|**(True or False) Generate the mean and standard deviation for all of the metrics created**| | ||
+ | |**RETAIN_NO_DATA_VALUES**|**(True or False) If the result is no_data, retain the value.**| | ||
+ | |||
+ | ====Dialog==== | ||
+ | |||
+ | The command can be edited in a text editor or in a dialog form. To edit in the dialog pop up form either click on the **Edit** button in the pipeline workshop or double-click on the pipeline command. The dialog is shown below. | ||
+ | {{: | ||
- | ---- | + | The dialog box allows you to assign values to the command parameters outlined above. |
==== Example ==== | ==== Example ==== | ||
Line 42: | Line 60: | ||
- | |< | + | |< |
visual3d/documentation/pipeline/metric_commands/metric_signal_values_in_sequence.1721158201.txt.gz · Last modified: 2024/07/16 19:30 by sgranger