visual3d:documentation:pipeline:metric_commands:metric_time_between_events
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:pipeline:metric_commands:metric_time_between_events [2025/09/19 13:30] – [Metric Time Between Events] wikisysop | visual3d:documentation:pipeline:metric_commands:metric_time_between_events [2025/09/19 13:36] (current) – wikisysop | ||
---|---|---|---|
Line 8: | Line 8: | ||
The command can be found in the **Pipeline Workshop** under **Metric**. | The command can be found in the **Pipeline Workshop** under **Metric**. | ||
- | ==== Metric_Time_Between_Events Command Details ==== | ||
- | Below are the details for this command: | + | ====Pipeline Command==== |
+ | The command syntax is as follows: | ||
+ | < | ||
+ | Metric_Time_Between_Events | ||
+ | / | ||
+ | ! / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ; | ||
+ | </ | ||
+ | |||
+ | ====Command Parameters==== | ||
+ | |||
+ | The following table shows the command | ||
|**Metric_Time_Between_Events** | |**Metric_Time_Between_Events** | ||
Line 20: | Line 35: | ||
|**! /Append to Existing Values=FALSE** | |**! /Append to Existing Values=FALSE** | ||
- | \\ | + | ====Dialog==== |
+ | |||
+ | The command can be edited in a text editor or in a dialog form. To edit in the dialog pop up form either click on the **Edit** button in the pipeline workshop or double-click on the pipeline command. The dialog is shown below. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | |||
+ | The dialog box allows you to assign values to the command parameters outlined above. | ||
+ | |||
+ | ====Examples==== | ||
In this example, consider the metric **Right_Terminal_Double_Limb_Support** which is the time between **LHS** and **RTO**. | In this example, consider the metric **Right_Terminal_Double_Limb_Support** which is the time between **LHS** and **RTO**. | ||
Line 34: | Line 59: | ||
</ | </ | ||
- | Below is the dialog that pops up when pipeline selection is edited by double clicking with the left mouse button. | ||
- | {{: | ||
**Note: Event_Sequence** - It is important to note that this command assumes that the events are specified in the correct order chronologically. | **Note: Event_Sequence** - It is important to note that this command assumes that the events are specified in the correct order chronologically. |
visual3d/documentation/pipeline/metric_commands/metric_time_between_events.1758288612.txt.gz · Last modified: 2025/09/19 13:30 by wikisysop