User Tools

Site Tools


visual3d:documentation:pipeline:signal_commands:gcvspl

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:documentation:pipeline:signal_commands:gcvspl [2024/10/24 15:14] – [ISB Information] wikisysopvisual3d:documentation:pipeline:signal_commands:gcvspl [2024/10/24 15:15] (current) wikisysop
Line 3: Line 3:
 GCVSPL was implemented based on the following article: GCVSPL was implemented based on the following article:
  
-\\ 
 **H.J. Woltring** (1986), A FORTRAN package for generalized, cross-validatory spline smoothing and differentiation. Advances in Engineering Software 8(2):104-113 (U.K.). **H.J. Woltring** (1986), A FORTRAN package for generalized, cross-validatory spline smoothing and differentiation. Advances in Engineering Software 8(2):104-113 (U.K.).
  
-\\ 
 The command is used like all other filter commands in Visual3D. The command is used like all other filter commands in Visual3D.
  
Line 60: Line 58:
 [[http://biomch-l.isbweb.org/threads/17045-Re-Woltring-Filter-cutt-off-frequency-VAL-P-value?highlight=spline+filter|From Biomch-L]] [[http://biomch-l.isbweb.org/threads/17045-Re-Woltring-Filter-cutt-off-frequency-VAL-P-value?highlight=spline+filter|From Biomch-L]]
  
- +<code> 
-First account for a pass butterworth filter (e.g. a fourth order butterworth filter)\\ +First account for a pass butterworth filter (e.g. a fourth order butterworth filter) 
-Modified_cut_off_freq= cut_off_freq / 0.802\\+Modified_cut_off_freq= cut_off_freq / 0.802
 Variance = sampling_freq/(2*PI*Modified_cut_off_freq)^(2*order) Variance = sampling_freq/(2*PI*Modified_cut_off_freq)^(2*order)
 +</code>
 === Cutoff Frequency Test === === Cutoff Frequency Test ===
  