visual3d:getting_started:testing_setup_checklist
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:getting_started:testing_setup_checklist [2024/07/16 19:33] – created sgranger | visual3d:getting_started:testing_setup_checklist [2024/07/26 14:32] (current) – wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== | + | ====== |
- | When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http:// | + | When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http:// |
There are many crucial steps in collecting " | There are many crucial steps in collecting " | ||
Line 7: | Line 7: | ||
The following checklist is a starting point from which Motion Capture Laboratories can build their own. | The following checklist is a starting point from which Motion Capture Laboratories can build their own. | ||
- | We encourage users to contribute to this list by sending additional tasks to support@c-motion.com | + | We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca. |
- | ==== Before Patient' | + | ===== Before Patient' |
- | === Turn on ALL systems === | + | ==== |
- | === Verify Position and Orientation === | + | ==== |
+ | |||
+ | 2.1 Verify the position and orientation of Motion Capture Cameras\\ | ||
+ | 2.2 Verify the position and orientation of Force Platforms\\ | ||
+ | 2.3 Verify the position and orientation of Force Structures\\ | ||
+ | 2.4 Verify the position and orientation of Obstacles or Environment objects\\ | ||
+ | |||
+ | ==== 3. Perform System Calibration ==== | ||
- | Verify the position | + | 3.1 Perform static |
- | Verify the position and orientation of Force Platforms | + | 3.2 Verify |
- | Verify the position and orientation of Force Structures | + | |
- | Verify the position and orientation of Obstacles or Environment objects | + | ==== |
- | === | + | |
- | Perform static and/or dynamic calibrations of data collection | + | 4.1 Verify the experimental protocol for the current |
- | Verify results against the Standards developed/ | + | |
- | === | + | ==== |
- | Verify the experimental protocol | + | 5.1 As per experimental protocol, set and verify |
- | === Set appropriate | + | * e.g. sampling rates (synchronise), |
- | As per experimental protocol, set and verify system settings | + | ==== |
- | e.g. sampling rates (synchronise), | + | |
- | === Zero Force Plates and Perform CalTester test === | + | |
- | Perform Caltester test at a minimum of 2 locations on each force platform | + | |
- | Verify against prior laboratory results | + | 6.2 Verify against prior laboratory results\\ |
- | === Prepare necessary markers and supplies === | + | |
+ | ==== | ||
- | ==== Patient' | + | ===== Patient' |
- | === Obtain informed consent === | + | ==== |
- | === Record subject details === | + | ==== |
- | Insure that there are no contraindications for the patient completing the data collection | + | |
- | This may include data collection done via questionnaires or measurements | + | |
- | If data collection includes patient questionnaires check to make sure that they have been completed correctly | + | |
- | === Apply markers as per experimental protocol === | + | |
- | Take a set of digital pictures of the subject for post-hoc review of the marker placement. | + | ==== |
- | === | + | |
- | Ensure all markers are visible | + | 10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\ |
- | === Verify recorded marker | + | |
- | Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol | + | ==== |
- | === | + | |
- | If necessary, remove anatomical | + | 11.1 Ensure all markers |
- | === Verify | + | |
+ | ==== | ||
- | If you switch to the real time mode in Visual3D, | + | 12.1 Verify recorded marker set by launching |
- | === | + | |
+ | ==== | ||
- | === Verify | + | 13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ |
+ | |||
+ | ==== | ||
- | Load data into Visual3D, | + | 14.1 If you switch to the real time mode in Visual3D, |
- | Remove assignments to partial force contacts | + | |
- | Remove assignments when two segments are in contact with the same platform. | + | ==== |
- | === | + | |
- | Verify that these event labels make intuitive sense. If not, data collection should be repeated | + | ==== 16. Verify force platform assignments |
- | ==== After Patient Leaves | + | |
- | === | + | 16.1 Load data into Visual3D, assign movement trials to model, and verify force platform assignments\\ |
+ | 16.2 Remove assignments to partial force contacts\\ | ||
+ | 16.3 Remove assignments when two segments are in contact with the same platform\\ | ||
+ | |||
+ | ==== | ||
- | === | + | 17.1 Verify that these event labels make intuitive sense. If not, data collection should be repeated\\ |
+ | |||
+ | ===== After Patient Leaves ===== | ||
- | === | + | ==== |
- | === Verify the report. === | + | ==== |
+ | |||
+ | ==== 20. Load Report Template ==== | ||
+ | |||
+ | ==== 21. Verify the report | ||