-====== Testing_Setup_Checklist ======+====== Testing Setup Checklist ======
  
-When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]]+When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]].
  
 There are many crucial steps in collecting "routine" motion capture data. There are many crucial steps in collecting "routine" motion capture data.
Line 7: Line 7:
 The following checklist is a starting point from which Motion Capture Laboratories can build their own. The following checklist is a starting point from which Motion Capture Laboratories can build their own.
  
-We encourage users to contribute to this list by sending additional tasks to support@c-motion.com+We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca.
  
-==== Before Patient's Arrival ====+===== Before Patient's Arrival =====
  
-===  Turn on ALL systems ===+====  1. Turn on ALL systems ====
  
-===  Verify Position and Orientation ===+====  2. Verify Position and Orientation ==== 
 +  
 + 2.1 Verify the position and orientation of Motion Capture Cameras\\ 
 + 2.2 Verify the position and orientation of Force Platforms\\ 
 + 2.3 Verify the position and orientation of Force Structures\\ 
 + 2.4 Verify the position and orientation of Obstacles or Environment objects\\ 
 +  
 +====  3. Perform System Calibration ====
  
-Verify the position and orientation of Motion Capture Cameras + 3.1 Perform static and/or dynamic calibrations of data collection devices\\ 
-Verify the position and orientation of Force Platforms + 3.2 Verify results against the Standards developed/referenced by your laboratory\\ 
-Verify the position and orientation of Force Structures +  
-Verify the position and orientation of Obstacles or Environment objects +====  4. Verify the protocol being used for the session ====
-===  Perform System Calibration ===+
  
-Perform static and/or dynamic calibrations of data collection devices + 4.1 Verify the experimental protocol for the current data collection session\\ 
-Verify results against the Standards developed/referenced by your laboratory +  
-===  Verify the protocol being used for the session ===+====  5. Set appropriate system settings ====
  
-Verify the experimental protocol for the current data collection session + 5.1 As per experimental protocol, set and verify system settings 
-===  Set appropriate system settings ===+  * e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc.\\
  
-As per experimental protocol, set and verify system settings +====  6. Zero Force Plates and Perform CalTester test ====
-e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc. +
-===  Zero Force Plates and Perform CalTester test ===+
  
-Perform Caltester test at a minimum of 2 locations on each force platform + 6.1 Perform Caltester test at a minimum of 2 locations on each force platform\\ 
-Verify against prior laboratory results + 6.2 Verify against prior laboratory results\\ 
-===  Prepare necessary markers and supplies ===+  
 +====  7. Prepare necessary markers and supplies ====
  
-==== Patient's Arrival ====+===== Patient's Arrival =====
  
-===  Obtain informed consent ===+====  8. Obtain informed consent ====
  
-===  Record subject details ===+====  9. Record subject details ====
  
-Insure that there are no contraindications for the patient completing the data collection + 9.1 Insure that there are no contraindications for the patient completing the data collection\\ 
-This may include data collection done via questionnaires or measurements +  This may include data collection done via questionnaires or measurements\\ 
-If data collection includes patient questionnaires check to make sure that they have been completed correctly +  If data collection includes patient questionnaires check to make sure that they have been completed correctly\\
-===  Apply markers as per experimental protocol ===+
  
-Take a set of digital pictures of the subject for post-hoc review of the marker placement. +====  10. Apply markers as per experimental protocol ====
-===  Record static calibration trial ===+
  
-Ensure all markers are visible + 10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\
-===  Verify recorded marker set ===+
  
-Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol +====  11. Record static calibration trial ====
-===  Remove anatomical markers ===+
  
-If necessary, remove anatomical markers not needed for tracking in motion trials + 11.1 Ensure all markers are visible\\ 
-===  Verify tracking using Real time ===+  
 +====  12. Verify recorded marker set ====
  
-If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense + 12.1 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol\\ 
-===  Record dynamic trials ===+  
 +====  13. Remove anatomical markers ====
  
-===  Verify force platform assignments ===+ 13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ 
 +  
 +====  14. Verify tracking using Real time ====
  
-Load data into Visual3D, assign movement trials to model, and verify force platform assignments + 14.1 If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense\\ 
-Remove assignments to partial force contacts +  
-Remove assignments when two segments are in contact with the same platform. +====  15Record dynamic trials ====
-===  Execute pipeline for creating event labels. ===+
  
-Verify that these event labels make intuitive sense. If not, data collection should be repeated +====  16. Verify force platform assignments ====
-==== After Patient Leaves ====+
  
-===  Clean up work station ===+ 16.1 Load data into Visual3D, assign movement trials to model, and verify force platform assignments\\ 
 + 16.2 Remove assignments to partial force contacts\\ 
 + 16.3 Remove assignments when two segments are in contact with the same platform\\ 
 +  
 +====  17. Execute pipeline for creating event labels ====
  
-===  Execute pipeline for processing ===+ 17.1 Verify that these event labels make intuitive sense. If not, data collection should be repeated\\ 
 +   
 +===== After Patient Leaves =====
  
-===  Load Report Template ===+====  18. Clean up work station ====
  
-===  Verify the report===+====  19. Execute pipeline for processing ==== 
 + 
 +====  20. Load Report Template ==== 
 + 
 +====  21. Verify the report ====
  
  
  