User Tools

Site Tools


visual3d:getting_started:testing_setup_checklist

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:getting_started:testing_setup_checklist [2024/07/26 14:23] wikisysopvisual3d:getting_started:testing_setup_checklist [2024/07/26 14:32] (current) wikisysop
Line 1: Line 1:
 ====== Testing Setup Checklist ====== ====== Testing Setup Checklist ======
  
-When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]]+When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]].
  
 There are many crucial steps in collecting "routine" motion capture data. There are many crucial steps in collecting "routine" motion capture data.
Line 7: Line 7:
 The following checklist is a starting point from which Motion Capture Laboratories can build their own. The following checklist is a starting point from which Motion Capture Laboratories can build their own.
  
-We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca+We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca.
  
 ===== Before Patient's Arrival ===== ===== Before Patient's Arrival =====
  
-====  Turn on ALL systems ====+====  1. Turn on ALL systems ====
  
-====  Verify Position and Orientation ====+====  2. Verify Position and Orientation ==== 
 +  
 + 2.1 Verify the position and orientation of Motion Capture Cameras\\ 
 + 2.2 Verify the position and orientation of Force Platforms\\ 
 + 2.3 Verify the position and orientation of Force Structures\\ 
 + 2.4 Verify the position and orientation of Obstacles or Environment objects\\ 
 +  
 +====  3. Perform System Calibration ====
  
-Verify the position and orientation of Motion Capture Cameras + 3.1 Perform static and/or dynamic calibrations of data collection devices\\ 
-Verify the position and orientation of Force Platforms + 3.2 Verify results against the Standards developed/referenced by your laboratory\\ 
-Verify the position and orientation of Force Structures +  
-Verify the position and orientation of Obstacles or Environment objects +====  4. Verify the protocol being used for the session ====
-====  Perform System Calibration ====+
  
-Perform static and/or dynamic calibrations of data collection devices + 4.1 Verify the experimental protocol for the current data collection session\\ 
-Verify results against the Standards developed/referenced by your laboratory +  
-====  Verify the protocol being used for the session ====+====  5. Set appropriate system settings ====
  
-Verify the experimental protocol for the current data collection session + 5.1 As per experimental protocol, set and verify system settings 
-====  Set appropriate system settings ====+  * e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc.\\
  
-As per experimental protocol, set and verify system settings +====  6. Zero Force Plates and Perform CalTester test ====
-e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc. +
-====  Zero Force Plates and Perform CalTester test ====+
  
-Perform Caltester test at a minimum of 2 locations on each force platform + 6.1 Perform Caltester test at a minimum of 2 locations on each force platform\\ 
-Verify against prior laboratory results + 6.2 Verify against prior laboratory results\\ 
-====  Prepare necessary markers and supplies ====+  
 +====  7. Prepare necessary markers and supplies ====
  
 ===== Patient's Arrival ===== ===== Patient's Arrival =====
  
-====  Obtain informed consent ====+====  8. Obtain informed consent ====
  
-====  Record subject details ====+====  9. Record subject details ====
  
-Insure that there are no contraindications for the patient completing the data collection + 9.1 Insure that there are no contraindications for the patient completing the data collection\\ 
-This may include data collection done via questionnaires or measurements +  This may include data collection done via questionnaires or measurements\\ 
-If data collection includes patient questionnaires check to make sure that they have been completed correctly +  If data collection includes patient questionnaires check to make sure that they have been completed correctly\\
-====  Apply markers as per experimental protocol ====+
  
-Take a set of digital pictures of the subject for post-hoc review of the marker placement. +====  10. Apply markers as per experimental protocol ====
-====  Record static calibration trial ====+
  
-Ensure all markers are visible + 10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\
-====  Verify recorded marker set ====+
  
-Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol +====  11. Record static calibration trial ====
-====  Remove anatomical markers ====+
  
-If necessary, remove anatomical markers not needed for tracking in motion trials + 11.1 Ensure all markers are visible\\ 
-====  Verify tracking using Real time ====+  
 +====  12. Verify recorded marker set ====
  
-If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense + 12.1 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol\\ 
-====  Record dynamic trials ====+  
 +====  13. Remove anatomical markers ====
  
-====  Verify force platform assignments ====+ 13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ 
 +  
 +====  14. Verify tracking using Real time ====
  
-Load data into Visual3D, assign movement trials to model, and verify force platform assignments + 14.1 If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense\\ 
-Remove assignments to partial force contacts +  
-Remove assignments when two segments are in contact with the same platform. +====  15Record dynamic trials ====
-====  Execute pipeline for creating event labels. ====+
  
-Verify that these event labels make intuitive sense. If not, data collection should be repeated+====  16. Verify force platform assignments ==== 
 + 
 + 16.1 Load data into Visual3D, assign movement trials to model, and verify force platform assignments\\ 
 + 16.2 Remove assignments to partial force contacts\\ 
 + 16.3 Remove assignments when two segments are in contact with the same platform\\ 
 +  
 +====  17. Execute pipeline for creating event labels ==== 
 + 
 + 17.1 Verify that these event labels make intuitive sense. If not, data collection should be repeated\\ 
 +  
 ===== After Patient Leaves ===== ===== After Patient Leaves =====
  
-====  Clean up work station ====+====  18. Clean up work station ====
  
-====  Execute pipeline for processing ====+====  19. Execute pipeline for processing ====
  
-====  Load Report Template ====+====  20. Load Report Template ====
  
-====  Verify the report====+====  21. Verify the report ====
  
  
  
visual3d/getting_started/testing_setup_checklist.1722003787.txt.gz · Last modified: 2024/07/26 14:23 by wikisysop