====== Testing Setup Checklist ====== | ====== Testing Setup Checklist ====== | ||
- | When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http:// | + | When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http:// |
There are many crucial steps in collecting " | There are many crucial steps in collecting " | ||
Line 7: | Line 7: | ||
The following checklist is a starting point from which Motion Capture Laboratories can build their own. | The following checklist is a starting point from which Motion Capture Laboratories can build their own. | ||
- | We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca | + | We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca. |
===== Before Patient' | ===== Before Patient' | ||
==== 1. Turn on ALL systems ==== | ==== 1. Turn on ALL systems ==== | ||
- | \\ | + | |
==== 2. Verify Position and Orientation ==== | ==== 2. Verify Position and Orientation ==== | ||
- | | + | 2.1 Verify the position and orientation of Motion Capture Cameras\\ |
- | 2.2 Verify the position and orientation of Force Platforms\\ | + | 2.2 Verify the position and orientation of Force Platforms\\ |
- | 2.3 Verify the position and orientation of Force Structures\\ | + | 2.3 Verify the position and orientation of Force Structures\\ |
- | 2.4 Verify the position and orientation of Obstacles or Environment objects\\ | + | 2.4 Verify the position and orientation of Obstacles or Environment objects\\ |
- | \\ | + | |
==== 3. Perform System Calibration ==== | ==== 3. Perform System Calibration ==== | ||
- | | + | 3.1 Perform static and/or dynamic calibrations of data collection devices\\ |
- | 3.2 Verify results against the Standards developed/ | + | 3.2 Verify results against the Standards developed/ |
- | \\ | + | |
==== 4. Verify the protocol being used for the session ==== | ==== 4. Verify the protocol being used for the session ==== | ||
- | | + | 4.1 Verify the experimental protocol for the current data collection session\\ |
- | \\ | + | |
==== 5. Set appropriate system settings ==== | ==== 5. Set appropriate system settings ==== | ||
- | | + | 5.1 As per experimental protocol, set and verify system settings |
- | | + | * e.g. sampling rates (synchronise), |
- | \\ | + | |
==== 6. Zero Force Plates and Perform CalTester test ==== | ==== 6. Zero Force Plates and Perform CalTester test ==== | ||
- | | + | 6.1 Perform Caltester test at a minimum of 2 locations on each force platform\\ |
- | 6.2 Verify against prior laboratory results\\ | + | 6.2 Verify against prior laboratory results\\ |
- | \\ | + | |
==== 7. Prepare necessary markers and supplies ==== | ==== 7. Prepare necessary markers and supplies ==== | ||
Line 47: | Line 47: | ||
==== 9. Record subject details ==== | ==== 9. Record subject details ==== | ||
- | | + | 9.1 Insure that there are no contraindications for the patient completing the data collection\\ |
- | | + | * This may include data collection done via questionnaires or measurements\\ |
- | | + | * If data collection includes patient questionnaires check to make sure that they have been completed correctly\\ |
- | \\ | + | |
==== 10. Apply markers as per experimental protocol ==== | ==== 10. Apply markers as per experimental protocol ==== | ||
- | | + | 10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\ |
- | \\ | + | |
==== 11. Record static calibration trial ==== | ==== 11. Record static calibration trial ==== | ||
- | | + | 11.1 Ensure all markers are visible\\ |
- | \\ | + | |
==== 12. Verify recorded marker set ==== | ==== 12. Verify recorded marker set ==== | ||
- | | + | 12.1 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol\\ |
- | \\ | + | |
==== 13. Remove anatomical markers ==== | ==== 13. Remove anatomical markers ==== | ||
- | | + | 13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ |
- | \\ | + | |
==== 14. Verify tracking using Real time ==== | ==== 14. Verify tracking using Real time ==== | ||
- | | + | 14.1 If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, |
- | \\ | + | |
==== 15. Record dynamic trials ==== | ==== 15. Record dynamic trials ==== | ||
==== 16. Verify force platform assignments ==== | ==== 16. Verify force platform assignments ==== | ||
- | | + | 16.1 Load data into Visual3D, assign movement trials to model, and verify force platform assignments\\ |
- | 16.2 Remove assignments to partial force contacts\\ | + | 16.2 Remove assignments to partial force contacts\\ |
- | 16.3 Remove assignments when two segments are in contact with the same platform\\ | + | 16.3 Remove assignments when two segments are in contact with the same platform\\ |
- | \\ | + | |
==== 17. Execute pipeline for creating event labels ==== | ==== 17. Execute pipeline for creating event labels ==== | ||
- | | + | 17.1 Verify that these event labels make intuitive sense. If not, data collection should be repeated\\ |
| | ||
- | ===== 18. After Patient Leaves ===== | + | ===== After Patient Leaves ===== |
- | ==== | + | ==== |
- | ==== | + | ==== |
- | ==== | + | ==== |
- | ==== | + | ==== |