User Tools

Site Tools


visual3d:getting_started:testing_setup_checklist

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:getting_started:testing_setup_checklist [2024/07/26 14:29] wikisysopvisual3d:getting_started:testing_setup_checklist [2024/07/26 14:32] (current) wikisysop
Line 1: Line 1:
 ====== Testing Setup Checklist ====== ====== Testing Setup Checklist ======
  
-When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]]+When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]].
  
 There are many crucial steps in collecting "routine" motion capture data. There are many crucial steps in collecting "routine" motion capture data.
Line 7: Line 7:
 The following checklist is a starting point from which Motion Capture Laboratories can build their own. The following checklist is a starting point from which Motion Capture Laboratories can build their own.
  
-We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca+We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca.
  
 ===== Before Patient's Arrival ===== ===== Before Patient's Arrival =====
  
 ====  1. Turn on ALL systems ==== ====  1. Turn on ALL systems ====
-\\+
 ====  2. Verify Position and Orientation ==== ====  2. Verify Position and Orientation ====
    
Line 19: Line 19:
  2.3 Verify the position and orientation of Force Structures\\  2.3 Verify the position and orientation of Force Structures\\
  2.4 Verify the position and orientation of Obstacles or Environment objects\\  2.4 Verify the position and orientation of Obstacles or Environment objects\\
-  \\+ 
 ====  3. Perform System Calibration ==== ====  3. Perform System Calibration ====
  
-  3.1 Perform static and/or dynamic calibrations of data collection devices\\ + 3.1 Perform static and/or dynamic calibrations of data collection devices\\ 
-  3.2 Verify results against the Standards developed/referenced by your laboratory\\ + 3.2 Verify results against the Standards developed/referenced by your laboratory\\ 
-  \\+ 
 ====  4. Verify the protocol being used for the session ==== ====  4. Verify the protocol being used for the session ====
  
-  4.1 Verify the experimental protocol for the current data collection session\\ + 4.1 Verify the experimental protocol for the current data collection session\\ 
-  \\+ 
 ====  5. Set appropriate system settings ==== ====  5. Set appropriate system settings ====
  
-  5.1 As per experimental protocol, set and verify system settings + 5.1 As per experimental protocol, set and verify system settings 
-   * e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc.\\ +  * e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc.\\ 
-\\+
 ====  6. Zero Force Plates and Perform CalTester test ==== ====  6. Zero Force Plates and Perform CalTester test ====
  
-  6.1 Perform Caltester test at a minimum of 2 locations on each force platform\\ + 6.1 Perform Caltester test at a minimum of 2 locations on each force platform\\ 
-  6.2 Verify against prior laboratory results\\ + 6.2 Verify against prior laboratory results\\ 
-  \\+ 
 ====  7. Prepare necessary markers and supplies ==== ====  7. Prepare necessary markers and supplies ====
  
Line 47: Line 47:
 ====  9. Record subject details ==== ====  9. Record subject details ====
  
-  9.1 Insure that there are no contraindications for the patient completing the data collection\\ + 9.1 Insure that there are no contraindications for the patient completing the data collection\\ 
-   * This may include data collection done via questionnaires or measurements\\ +  * This may include data collection done via questionnaires or measurements\\ 
-   * If data collection includes patient questionnaires check to make sure that they have been completed correctly\\ +  * If data collection includes patient questionnaires check to make sure that they have been completed correctly\\ 
-\\+
 ====  10. Apply markers as per experimental protocol ==== ====  10. Apply markers as per experimental protocol ====
  
-  10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\ + 10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\ 
-\\+
 ====  11. Record static calibration trial ==== ====  11. Record static calibration trial ====
  
-  11.1 Ensure all markers are visible\\ + 11.1 Ensure all markers are visible\\ 
-  \\+ 
 ====  12. Verify recorded marker set ==== ====  12. Verify recorded marker set ====
  
-  12.1 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol\\ + 12.1 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol\\ 
-  \\+ 
 ====  13. Remove anatomical markers ==== ====  13. Remove anatomical markers ====
  
-  13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ + 13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ 
-  \\+ 
 ====  14. Verify tracking using Real time ==== ====  14. Verify tracking using Real time ====
  
-  14.1 If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense\\ + 14.1 If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense\\ 
-  \\+ 
 ====  15. Record dynamic trials ==== ====  15. Record dynamic trials ====
  
 ====  16. Verify force platform assignments ==== ====  16. Verify force platform assignments ====
  
-  16.1 Load data into Visual3D, assign movement trials to model, and verify force platform assignments\\ + 16.1 Load data into Visual3D, assign movement trials to model, and verify force platform assignments\\ 
-  16.2 Remove assignments to partial force contacts\\ + 16.2 Remove assignments to partial force contacts\\ 
-  16.3 Remove assignments when two segments are in contact with the same platform\\ + 16.3 Remove assignments when two segments are in contact with the same platform\\ 
-  \\+ 
 ====  17. Execute pipeline for creating event labels ==== ====  17. Execute pipeline for creating event labels ====
  
-  17.1 Verify that these event labels make intuitive sense. If not, data collection should be repeated\\+ 17.1 Verify that these event labels make intuitive sense. If not, data collection should be repeated\\
      
 ===== After Patient Leaves ===== ===== After Patient Leaves =====
visual3d/getting_started/testing_setup_checklist.1722004155.txt.gz · Last modified: 2024/07/26 14:29 by wikisysop