visual3d:getting_started:testing_setup_checklist
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:getting_started:testing_setup_checklist [2024/07/26 14:30] – wikisysop | visual3d:getting_started:testing_setup_checklist [2024/07/26 14:32] (current) – wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Testing Setup Checklist ====== | ====== Testing Setup Checklist ====== | ||
- | When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http:// | + | When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http:// |
There are many crucial steps in collecting " | There are many crucial steps in collecting " | ||
Line 7: | Line 7: | ||
The following checklist is a starting point from which Motion Capture Laboratories can build their own. | The following checklist is a starting point from which Motion Capture Laboratories can build their own. | ||
- | We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca | + | We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca. |
===== Before Patient' | ===== Before Patient' | ||
==== 1. Turn on ALL systems ==== | ==== 1. Turn on ALL systems ==== | ||
- | \\ | + | |
==== 2. Verify Position and Orientation ==== | ==== 2. Verify Position and Orientation ==== | ||
Line 19: | Line 19: | ||
2.3 Verify the position and orientation of Force Structures\\ | 2.3 Verify the position and orientation of Force Structures\\ | ||
2.4 Verify the position and orientation of Obstacles or Environment objects\\ | 2.4 Verify the position and orientation of Obstacles or Environment objects\\ | ||
- | \\ | + | |
==== 3. Perform System Calibration ==== | ==== 3. Perform System Calibration ==== | ||
3.1 Perform static and/or dynamic calibrations of data collection devices\\ | 3.1 Perform static and/or dynamic calibrations of data collection devices\\ | ||
3.2 Verify results against the Standards developed/ | 3.2 Verify results against the Standards developed/ | ||
- | \\ | + | |
==== 4. Verify the protocol being used for the session ==== | ==== 4. Verify the protocol being used for the session ==== | ||
4.1 Verify the experimental protocol for the current data collection session\\ | 4.1 Verify the experimental protocol for the current data collection session\\ | ||
- | \\ | + | |
==== 5. Set appropriate system settings ==== | ==== 5. Set appropriate system settings ==== | ||
5.1 As per experimental protocol, set and verify system settings | 5.1 As per experimental protocol, set and verify system settings | ||
* e.g. sampling rates (synchronise), | * e.g. sampling rates (synchronise), | ||
- | \\ | + | |
==== 6. Zero Force Plates and Perform CalTester test ==== | ==== 6. Zero Force Plates and Perform CalTester test ==== | ||
6.1 Perform Caltester test at a minimum of 2 locations on each force platform\\ | 6.1 Perform Caltester test at a minimum of 2 locations on each force platform\\ | ||
6.2 Verify against prior laboratory results\\ | 6.2 Verify against prior laboratory results\\ | ||
- | \\ | + | |
==== 7. Prepare necessary markers and supplies ==== | ==== 7. Prepare necessary markers and supplies ==== | ||
Line 48: | Line 48: | ||
9.1 Insure that there are no contraindications for the patient completing the data collection\\ | 9.1 Insure that there are no contraindications for the patient completing the data collection\\ | ||
- | * This may include data collection done via questionnaires or measurements\\ | + | |
* If data collection includes patient questionnaires check to make sure that they have been completed correctly\\ | * If data collection includes patient questionnaires check to make sure that they have been completed correctly\\ | ||
- | \\ | + | |
==== 10. Apply markers as per experimental protocol ==== | ==== 10. Apply markers as per experimental protocol ==== | ||
10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\ | 10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\ | ||
- | \\ | + | |
==== 11. Record static calibration trial ==== | ==== 11. Record static calibration trial ==== | ||
11.1 Ensure all markers are visible\\ | 11.1 Ensure all markers are visible\\ | ||
- | \\ | + | |
==== 12. Verify recorded marker set ==== | ==== 12. Verify recorded marker set ==== | ||
12.1 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol\\ | 12.1 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol\\ | ||
- | \\ | + | |
==== 13. Remove anatomical markers ==== | ==== 13. Remove anatomical markers ==== | ||
13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ | 13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ | ||
- | \\ | + | |
==== 14. Verify tracking using Real time ==== | ==== 14. Verify tracking using Real time ==== | ||
14.1 If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, | 14.1 If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, | ||
- | \\ | + | |
==== 15. Record dynamic trials ==== | ==== 15. Record dynamic trials ==== | ||
Line 78: | Line 78: | ||
16.2 Remove assignments to partial force contacts\\ | 16.2 Remove assignments to partial force contacts\\ | ||
16.3 Remove assignments when two segments are in contact with the same platform\\ | 16.3 Remove assignments when two segments are in contact with the same platform\\ | ||
- | \\ | + | |
==== 17. Execute pipeline for creating event labels ==== | ==== 17. Execute pipeline for creating event labels ==== | ||
visual3d/getting_started/testing_setup_checklist.1722004200.txt.gz · Last modified: 2024/07/26 14:30 by wikisysop