User Tools

Site Tools


visual3d:overview:testing_setup_checklist

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
visual3d:overview:testing_setup_checklist [2024/06/14 17:31] – created sgrangervisual3d:overview:testing_setup_checklist [2024/07/12 13:31] (current) – removed sgranger
Line 1: Line 1:
-|**Language:**|** English**  • [[Testing_Setup_Checklist/fr|français]] • [[index.php?title=Testing_Setup_Checklist/it&action=edit&redlink=1|italiano]] • [[Testing_Setup_Checklist/pt|português]] • [[index.php?title=Testing_Setup_Checklist/es&action=edit&redlink=1|español]] ****| 
- 
-|===== Contents =====\\ \\ \\ \\ * [[#Before_Patient's_Arrival|1 Before Patient's Arrival]]\\   * [[#Turn_on_ALL_systems|1.1 Turn on ALL systems]]\\   * [[#Verify_Position_and_Orientation|1.2 Verify Position and Orientation]]\\   * [[#Perform_System_Calibration|1.3 Perform System Calibration]]\\   * [[#Verify_the_protocol_being_used_for_the_session|1.4 Verify the protocol being used for the session]]\\   * [[#Set_appropriate_system_settings|1.5 Set appropriate system settings]]\\   * [[#Zero_Force_Plates_and_Perform_CalTester_test|1.6 Zero Force Plates and Perform CalTester test]]\\   * [[#Prepare_necessary_markers_and_supplies|1.7 Prepare necessary markers and supplies]]\\ * [[#Patient's_Arrival|2 Patient's Arrival]]\\   * [[#Obtain_informed_consent|2.1 Obtain informed consent]]\\   * [[#Record_subject_details|2.2 Record subject details]]\\   * [[#Apply_markers_as_per_experimental_protocol|2.3 Apply markers as per experimental protocol]]\\   * [[#Record_static_calibration_trial|2.4 Record static calibration trial]]\\   * [[#Verify_recorded_marker_set|2.5 Verify recorded marker set]]\\   * [[#Remove_anatomical_markers|2.6 Remove anatomical markers]]\\   * [[#Verify_tracking_using_Real_time|2.7 Verify tracking using Real time]]\\   * [[#Record_dynamic_trials|2.8 Record dynamic trials]]\\   * [[#Verify_force_platform_assignments|2.9 Verify force platform assignments]]\\   * [[#Execute_pipeline_for_creating_event_labels.|2.10 Execute pipeline for creating event labels.]]\\ * [[#After_Patient_Leaves|3 After Patient Leaves]]\\   * [[#Clean_up_work_station|3.1 Clean up work station]]\\   * [[#Execute_pipeline_for_processing|3.2 Execute pipeline for processing]]\\   * [[#Load_Report_Template|3.3 Load Report Template]]\\   * [[#Verify_the_report.|3.4 Verify the report.]]| 
- 
-When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]] 
- 
-There are many crucial steps in collecting "routine" motion capture data. 
- 
-The following checklist is a starting point from which Motion Capture Laboratories can build their own. 
- 
-We encourage users to contribute to this list by sending additional tasks to support@c-motion.com 
- 
-===== Before Patient's Arrival ===== 
- 
-====  Turn on ALL systems ==== 
- 
-====  Verify Position and Orientation ==== 
- 
-Verify the position and orientation of Motion Capture Cameras 
-Verify the position and orientation of Force Platforms 
-Verify the position and orientation of Force Structures 
-Verify the position and orientation of Obstacles or Environment objects 
-====  Perform System Calibration ==== 
- 
-Perform static and/or dynamic calibrations of data collection devices 
-Verify results against the Standards developed/referenced by your laboratory 
-====  Verify the protocol being used for the session ==== 
- 
-Verify the experimental protocol for the current data collection session 
-====  Set appropriate system settings ==== 
- 
-As per experimental protocol, set and verify system settings 
-e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc. 
-====  Zero Force Plates and Perform CalTester test ==== 
- 
-Perform Caltester test at a minimum of 2 locations on each force platform 
-Verify against prior laboratory results 
-====  Prepare necessary markers and supplies ==== 
- 
-===== Patient's Arrival ===== 
- 
-====  Obtain informed consent ==== 
- 
-====  Record subject details ==== 
- 
-Insure that there are no contraindications for the patient completing the data collection 
-This may include data collection done via questionnaires or measurements 
-If data collection includes patient questionnaires check to make sure that they have been completed correctly 
-====  Apply markers as per experimental protocol ==== 
- 
-Take a set of digital pictures of the subject for post-hoc review of the marker placement. 
-====  Record static calibration trial ==== 
- 
-Ensure all markers are visible 
-====  Verify recorded marker set ==== 
- 
-Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol 
-====  Remove anatomical markers ==== 
- 
-If necessary, remove anatomical markers not needed for tracking in motion trials 
-====  Verify tracking using Real time ==== 
- 
-If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense 
-====  Record dynamic trials ==== 
- 
-====  Verify force platform assignments ==== 
- 
-Load data into Visual3D, assign movement trials to model, and verify force platform assignments 
-Remove assignments to partial force contacts 
-Remove assignments when two segments are in contact with the same platform. 
-====  Execute pipeline for creating event labels. ==== 
- 
-Verify that these event labels make intuitive sense. If not, data collection should be repeated 
-===== After Patient Leaves ===== 
- 
-====  Clean up work station ==== 
- 
-====  Execute pipeline for processing ==== 
- 
-====  Load Report Template ==== 
- 
-====  Verify the report. ==== 
- 
- 
-Retrieved from "" 
- 
  
visual3d/overview/testing_setup_checklist.1718386290.txt.gz · Last modified: 2024/06/14 17:31 by sgranger