- | When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http:// | ||
- | |||
- | There are many crucial steps in collecting " | ||
- | |||
- | The following checklist is a starting point from which Motion Capture Laboratories can build their own. | ||
- | |||
- | We encourage users to contribute to this list by sending additional tasks to support@c-motion.com | ||
- | |||
- | ===== Before Patient' | ||
- | |||
- | ==== Turn on ALL systems ==== | ||
- | |||
- | ==== Verify Position and Orientation ==== | ||
- | |||
- | Verify the position and orientation of Motion Capture Cameras | ||
- | Verify the position and orientation of Force Platforms | ||
- | Verify the position and orientation of Force Structures | ||
- | Verify the position and orientation of Obstacles or Environment objects | ||
- | ==== Perform System Calibration ==== | ||
- | |||
- | Perform static and/or dynamic calibrations of data collection devices | ||
- | Verify results against the Standards developed/ | ||
- | ==== Verify the protocol being used for the session ==== | ||
- | |||
- | Verify the experimental protocol for the current data collection session | ||
- | ==== Set appropriate system settings ==== | ||
- | |||
- | As per experimental protocol, set and verify system settings | ||
- | e.g. sampling rates (synchronise), | ||
- | ==== Zero Force Plates and Perform CalTester test ==== | ||
- | |||
- | Perform Caltester test at a minimum of 2 locations on each force platform | ||
- | Verify against prior laboratory results | ||
- | ==== Prepare necessary markers and supplies ==== | ||
- | |||
- | ===== Patient' | ||
- | |||
- | ==== Obtain informed consent ==== | ||
- | |||
- | ==== Record subject details ==== | ||
- | |||
- | Insure that there are no contraindications for the patient completing the data collection | ||
- | This may include data collection done via questionnaires or measurements | ||
- | If data collection includes patient questionnaires check to make sure that they have been completed correctly | ||
- | ==== Apply markers as per experimental protocol ==== | ||
- | |||
- | Take a set of digital pictures of the subject for post-hoc review of the marker placement. | ||
- | ==== Record static calibration trial ==== | ||
- | |||
- | Ensure all markers are visible | ||
- | ==== Verify recorded marker set ==== | ||
- | |||
- | Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol | ||
- | ==== Remove anatomical markers ==== | ||
- | |||
- | If necessary, remove anatomical markers not needed for tracking in motion trials | ||
- | ==== Verify tracking using Real time ==== | ||
- | |||
- | If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, | ||
- | ==== Record dynamic trials ==== | ||
- | |||
- | ==== Verify force platform assignments ==== | ||
- | |||
- | Load data into Visual3D, assign movement trials to model, and verify force platform assignments | ||
- | Remove assignments to partial force contacts | ||
- | Remove assignments when two segments are in contact with the same platform. | ||
- | ==== Execute pipeline for creating event labels. ==== | ||
- | |||
- | Verify that these event labels make intuitive sense. If not, data collection should be repeated | ||
- | ===== After Patient Leaves ===== | ||
- | |||
- | ==== Clean up work station ==== | ||
- | |||
- | ==== Execute pipeline for processing ==== | ||
- | |||
- | ==== Load Report Template ==== | ||
- | |||
- | ==== Verify the report. ==== | ||
- | |||
- | |||
- | |||
- | |||