User Tools

Site Tools


visual3d:overview:testing_setup_checklist

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:overview:testing_setup_checklist [2024/06/26 20:30] – created sgrangervisual3d:overview:testing_setup_checklist [2024/07/12 13:31] (current) – removed sgranger
Line 1: Line 1:
-====== Testing_Setup_Checklist ====== 
- 
-When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]] 
- 
-There are many crucial steps in collecting "routine" motion capture data. 
- 
-The following checklist is a starting point from which Motion Capture Laboratories can build their own. 
- 
-We encourage users to contribute to this list by sending additional tasks to support@c-motion.com 
- 
-==== Before Patient's Arrival ==== 
- 
-===  Turn on ALL systems === 
- 
-===  Verify Position and Orientation === 
- 
-Verify the position and orientation of Motion Capture Cameras 
-Verify the position and orientation of Force Platforms 
-Verify the position and orientation of Force Structures 
-Verify the position and orientation of Obstacles or Environment objects 
-===  Perform System Calibration === 
- 
-Perform static and/or dynamic calibrations of data collection devices 
-Verify results against the Standards developed/referenced by your laboratory 
-===  Verify the protocol being used for the session === 
- 
-Verify the experimental protocol for the current data collection session 
-===  Set appropriate system settings === 
- 
-As per experimental protocol, set and verify system settings 
-e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc. 
-===  Zero Force Plates and Perform CalTester test === 
- 
-Perform Caltester test at a minimum of 2 locations on each force platform 
-Verify against prior laboratory results 
-===  Prepare necessary markers and supplies === 
- 
-==== Patient's Arrival ==== 
- 
-===  Obtain informed consent === 
- 
-===  Record subject details === 
- 
-Insure that there are no contraindications for the patient completing the data collection 
-This may include data collection done via questionnaires or measurements 
-If data collection includes patient questionnaires check to make sure that they have been completed correctly 
-===  Apply markers as per experimental protocol === 
- 
-Take a set of digital pictures of the subject for post-hoc review of the marker placement. 
-===  Record static calibration trial === 
- 
-Ensure all markers are visible 
-===  Verify recorded marker set === 
- 
-Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol 
-===  Remove anatomical markers === 
- 
-If necessary, remove anatomical markers not needed for tracking in motion trials 
-===  Verify tracking using Real time === 
- 
-If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense 
-===  Record dynamic trials === 
- 
-===  Verify force platform assignments === 
- 
-Load data into Visual3D, assign movement trials to model, and verify force platform assignments 
-Remove assignments to partial force contacts 
-Remove assignments when two segments are in contact with the same platform. 
-===  Execute pipeline for creating event labels. === 
- 
-Verify that these event labels make intuitive sense. If not, data collection should be repeated 
-==== After Patient Leaves ==== 
- 
-===  Clean up work station === 
- 
-===  Execute pipeline for processing === 
- 
-===  Load Report Template === 
- 
-===  Verify the report. === 
- 
- 
  
visual3d/overview/testing_setup_checklist.1719433825.txt.gz · Last modified: 2024/06/26 20:30 by sgranger