User Tools

Site Tools


visual3d:real_time_streaming:real-time_pipeline_and_biofeedback

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:real_time_streaming:real-time_pipeline_and_biofeedback [2024/07/16 19:33] – created sgrangervisual3d:real_time_streaming:real-time_pipeline_and_biofeedback [2025/06/27 17:03] (current) – [RT_Graphs] wikisysop
Line 1: Line 1:
-====== Real-time_Pipeline_and_Biofeedback ======+====== Real-time Pipeline and Biofeedback ======
  
 [[Visual3D:Tutorials:Real_Time:Biofeedback:RT_Biofeedback_Overview|Tutorial_RT_Biofeedback]] [[Visual3D:Tutorials:Real_Time:Biofeedback:RT_Biofeedback_Overview|Tutorial_RT_Biofeedback]]
  
-==== RT Pipeline ====+===== RT Pipeline =====
  
 For each packet of streaming data received by Visual3D. For each packet of streaming data received by Visual3D.
Line 10: Line 10:
   * The RT pipeline is executed.   * The RT pipeline is executed.
  
-{{RT_Pipeline1.jpg}}+{{:RT_Pipeline1.jpg}}
  
 The RT Pipeline contains a subset of the commands in the Post Processing pipeline because only some of the commands make sense in the real time stream. The RT Pipeline contains a subset of the commands in the Post Processing pipeline because only some of the commands make sense in the real time stream.
  
-=== RT_ModelBased ===+==== RT_ModelBased ====
  
-{{RT_Pipeline2.jpg}}+{{:RT_Pipeline2.jpg}}
  
-=== RT_Events ===+==== RT_Events ===
  
 Only two of the Events commands exist. Only two of the Events commands exist.
  
-{{RT_Pipeline3.jpg}}+{{:RT_Pipeline3.jpg}}
  
 Note that automatic_gait_events relies on the Forces being assigned to a segment. Note that automatic_gait_events relies on the Forces being assigned to a segment.
  
-=== RT_SignalMath ===+==== RT_SignalMath ====
  
-{{RT_Pipeline4.jpg}}+{{:RT_Pipeline4.jpg}}
  
 ==== RT_Graphs ==== ==== RT_Graphs ====
  
-{{RT_Pipeline5.jpg}}+{{:RT_Pipeline5.jpg}}
  
 === RT_Graph_Dialog === === RT_Graph_Dialog ===
Line 42: Line 42:
 The Adjust Graph Position option is a new feature that allows the user to manually move the graphs around. The Adjust Graph Position option is a new feature that allows the user to manually move the graphs around.
  
-<code> +  - Typical values should be between -2 and 2. Exceeding those values may send the graph outside of the normal viewing area. 
-- Typical values should be between -2 and 2. Exceeding those values may send the graph outside of the normal viewing area. +  - The position adjustment stacks on top of the row / column location, so adjust the row / column first and then make any fine adjustments using the new feature.
-- The position adjustment stacks on top of the row / column location, so adjust the row / column first and then make any fine adjustments using the new feature. +
-</code>+
  
-{{RT_Pipeline6.jpg}}+{{:RT_Pipeline6.jpg?500}}
  
  
  
visual3d/real_time_streaming/real-time_pipeline_and_biofeedback.1721158392.txt.gz · Last modified: 2024/07/16 19:33 by sgranger