visual3d:tutorials:real_time:biofeedback:vicon_nexus
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:tutorials:real_time:biofeedback:vicon_nexus [2025/09/22 19:25] – [Step 3 - Visual3D Real-Time Set Up] wikisysop | visual3d:tutorials:real_time:biofeedback:vicon_nexus [2025/09/23 18:57] (current) – [Step 5 - Create Graph] wikisysop | ||
---|---|---|---|
Line 15: | Line 15: | ||
**Before streaming in real time, Nexus must be running and the subject calibration trial must be labeled. This allows Nexus to label markers in " | **Before streaming in real time, Nexus must be running and the subject calibration trial must be labeled. This allows Nexus to label markers in " | ||
- | |1. Calibrating the capture volume Nexus using the software' | + | |1. Calibrating the capture volume Nexus using the software' |
|3. Collect a static trial.\\ \\ 4. From data managent, load the static trial and label the marker trajectories.(image on right) | |3. Collect a static trial.\\ \\ 4. From data managent, load the static trial and label the marker trajectories.(image on right) | ||
Line 32: | Line 32: | ||
OPTION 2 - You can collect a static trial in Visual3D.\\ | OPTION 2 - You can collect a static trial in Visual3D.\\ | ||
\\ | \\ | ||
- | **I recommend using the static trial collected in Nexus (Option 1).**\\ | + | **Its recommended to use the static trial collected in Nexus (Option 1).**\\ |
\\ | \\ | ||
**OPTION 1 -**\\ | **OPTION 1 -**\\ | ||
Line 54: | Line 54: | ||
==== Step 3 - Visual3D Real-Time Set Up ==== | ==== Step 3 - Visual3D Real-Time Set Up ==== | ||
+ | |1. Launch V3D (V3D main screen).|{{: | ||
- | 1. Launch V3D (V3D main screen)\\ | + | |2. Select the Real-time capture TAB|\\ |
- | \\ | + | |3. a) In the dialog box you should see your plug in %%__%%%%__%%%%__%%.dlls Click Vicon_Nexus_RT.|{{: |
- | {{: | + | |
- | + | ||
- | + | ||
- | \\ | + | |
- | 2. Select the Real-time capture TAB\\ | + | |
- | + | ||
- | + | ||
- | 3. a) In the dialog box you should see your plug in %%__%%%%__%%%%__%%.dlls Click Vicon_Nexus_RT.\\ | + | |
- | + | ||
- | + | ||
- | \\ | + | |
- | {{: | + | |
- | + | ||
- | + | ||
- | \\ | + | |
- | 3. b) A dialog box will appear to select your current Nexus System file. When using standard Nexus file structure, the system file should be located under: C: | + | |
- | + | ||
- | + | ||
- | {{: | + | |
+ | |3. b) A dialog box will appear to select your current Nexus System file. When using standard Nexus file structure, the system file should be located under: C: | ||
\\ | \\ | ||
Line 93: | Line 76: | ||
After having created or loaded a model, and established connection with the system back in the Real-Time tab, it is then possible to compute any model based item through the real-time pipeline. | After having created or loaded a model, and established connection with the system back in the Real-Time tab, it is then possible to compute any model based item through the real-time pipeline. | ||
- | < | + | -Open up: Model Based Data Computation under the **Real-Time Pipeline** |
- | < | + | -Double click, Compute_Model_Based_Data |
- | < | + | -Click **Edit** |
- | < | + | {{: |
- | {{: | + | Change the corresponding: |
- | < | + | \\ |
+ | < | ||
**Data Name:** Ankle | **Data Name:** Ankle | ||
**Folder:** ORIGINAL | **Folder:** ORIGINAL | ||
**Model Based Item Properties: | **Model Based Item Properties: | ||
**Segment: | **Segment: | ||
- | **Reference Segment:** Right Shank\\ | + | **Reference Segment:** Right Shank |
+ | </ | ||
- | {{: | + | {{: |
- | < | + | |
+ | Click **Done**\\ | ||
==== Step 5 - Create Graph ==== | ==== Step 5 - Create Graph ==== | ||
- | < | + | -Click **Add** in the **Real-Time Graphs** section, and enter the following: |
- | < | + | |
**Data to:** LINK_MODEL_BASED:: | **Data to:** LINK_MODEL_BASED:: | ||
- | {{: | + | {{: |
- | < | + | |
- | \\ | ||
Your result should show a Real-Time stream that looks like the picture below | Your result should show a Real-Time stream that looks like the picture below | ||
visual3d/tutorials/real_time/biofeedback/vicon_nexus.1758569122.txt.gz · Last modified: 2025/09/22 19:25 by wikisysop