visual3d:documentation:pipeline:other_commands:set_use_processed_analog
Table of Contents
Set Use Processed Analog
This command sets a flag that causes Visual3D to use the PROCESSED ANALOG signals for computing the Ground Reaction Force and External Force signals.
NOTE: In general the automatic identification of contact with the force platforms is based on the ORIGINAL FORCE signals. Users should be careful selecting to use PROCESSED ANALOG signals because of the inherent roll-off caused by filtering the signal.
Pipeline Command
Set_Use_Processed_Analog /USE_PROCESSED=FALSE ;
Notes
Instrumented treadmills and stairs seem to be an exception to this rule because the FORCE signals are substantially better if the ANALOG signals are filtered rather than the FORCE signals.
See Also
You can also manually set to use the processed signals by going to Settings → Use Processed Analog for Ground Reaction Force Calculations.