Import Analog NDI Signals
Imports NDI Analog signals from a V# or O# formatted file into an existing C3D file. If the Analog rate is not an integer multiple of the Point rate, the Analog data will be resampled.
Import_Analog_NDI_Signals ! /C3D_FILE_NAME= ! /IMPORT_FILE_NAME= ! /UPDATE_C3D_FILE=FALSE ! /REPLACE_EXISTING_SIGNALS=FALSE ! /DELETE_ALL_EXISTING_SIGNALS=FALSE ;
It is recommended that users translate the C# files into C3D files, then import the analog files.