User Tools

Site Tools


visual3d:documentation:pipeline:file_commands:import_analog_signals_from_fsv_file

Import Analog Signals From Fsv File

The FSV/TSV file formats were originally developed by Manfred Berger from Innovision Systems and are currently used by Qualisys and Innovision.

Import_Analog_Signals_From_Fsv_File ! /REPLACE_EXISTING_SIGNALS=TRUE ; It is assumed that the analog file has a name consistent with the c3d file name. For example:

file.c3d and file_a.fsv

if the option to overwrite signals is selected, new signals of the same name as an existing signal will have a number attached to them to identify them.

Analog1 would become Analog1_2

The FSV ANALOG file format is:


DESCRIPTION John Smith
NO_OF_SAMPLES 2000
TOT_NO_OF_CHAN4
FREQUENCY 1000
TIME_STAMP 8/1/2006
CHANNEL_NAMES EMG1 EMG2EMG3
CHANNEL_UNITS V V V
CHANNEL_GAIN 1 1 1
0 0 0
0 0 0
visual3d/documentation/pipeline/file_commands/import_analog_signals_from_fsv_file.txt · Last modified: 2024/07/17 11:45 by sgranger