User Tools

Site Tools


visual3d:documentation:pipeline:file_commands:import_signals_from_c3d_file

Import Signals From C3D File

This command imports signals from a C3D file into the active file.

Import_Signals_From_C3D_File**
! /FILE_NAME=
! /IMPORT_FILE_NAME=
! /REPLACE_EXISTING_SIGNALS=FALSE
! /SYNCH_OFFSET=
! /IMPORT_ANALOG_SYNCH=
! /IMPORT_ANALOG_THRESHOLD=0.0
! /IMPORT_ANALOG_ASCENDING=TRUE
! /ANALOG_RATE=
! /ANALOG_RATIO=
! /ALLOW_RESAMPLE=FALSE
! /INTERPOLATION_METHOD=CUBIC_SPLINE
! /IMPORT_AS_DERIVED=FALSE
! /DERIVED_FOLDER=EMG
! /IMPORT_FORCE_PLATFORM_PARAMETERS=FALSE
! /ADD_PREFIX_TO_IMPORT=
;

Important Notes

Only ANALOG and ROTATION signals can be imported. SYNCH Pulses are assumed to be analog signals.

If analog signals already exist in the c3d file, and the imported analog signals are at a different sampling rate, these new signals must be imported as DERIVED signals.

Example

Under construction…

Back to Pipeline Commands Reference