User Tools

Site Tools


visual3d:documentation:pipeline:metric_commands:metric_compute_gait_signal_stats

This is an old revision of the document!


Metric Compute Gait Signal Stats

Overview

These discrete gain metrics are part of the common cohort of Gait Parameters.

This command is used to create user defined statistics for a set of signals. It can be found in the Pipeline Workshop within the Metric folder. The following stats are computed for the signals selected for each side of the body selected.

Signal value at Heel Strike

HS Avg - Average value at Heel Strike HS SD - Standard Deviation of the value of the signal at Heel Strike Signal value at Toe Off

TO Avg - Average value at Heel Strike TO SD - Standard Deviation of the value of the signal at Heel Strike Values during Stance Phase

Avg Stance = SD Stance Min Stance Min Stance SD Time at Min Stance (Avg) Time at Min Stance (SD) Max Stance Max Stance SD Time at Max Stance (Avg) Time at Max Stance (SD) Values during Swing Phase

Avg Swing SD Swing Min Swing Min SwingSD Time at Min Swing(Avg) Time at Min Swing(SD) Max Swing Max SwingSD Time at Max Swing(Avg) Time at Max Swing(SD) Occurences of stance, swing, and cycle

Stance (Count) = number of stance phases used Swing (Count)= number of swing phases used Cycle (Count)= number of cycles used.

Pipeline Command

The pipeline command is as follows:

Metric_Compute_Gait_Signal_Stats
/SIGNAL_TYPES=
! /SIGNAL_FOLDER=ORIGINAL
! /SIGNAL_NAMES=
! /SIGNAL_COMPONENTS=
! /COMPONENT_SEQUENCE=
/COMPUTE_LEFT_SIDE=
/COMPUTE_RIGHT_SIDE=
! /RESULT_FOLDER=SIGNAL_STATS
! /RHS_EVENT=RHS
! /LHS_EVENT=LHS
! /RTO_EVENT=RTO
! /LTO_EVENT=LTO
! /LEFT_SIDE_RESULT_NAME_PREFIX=L_
! /RIGHT_SIDE_RESULT_NAME_PREFIX=R_
! /RESULT_NAME_SUFFIX=_Stats
! /APPEND_COMPONENT_TO_RESULT_NAME=FALSE
! /MERGE_COMPONENTS=FALSE
;

Command Parameters

The following table shows the command parameters and descriptions:

SIGNAL_TYPES Specify signal types
SIGNAL_FOLDERSpecify signal folder
SIGNAL_NAMESSpecify signal names
SIGNAL_COMPONENTSEach component of the signal will generate a metric signal containing the coefficients for that component of the signal.
COMPONENT_SEQUENCEWhich component of the signal will be used for statistical analysis of the sequence.
COMPUTE_LEFT/RIGHT_SIDEWhich side events will be computed for.
RESULT_FOLDERAssigning folder to hold results.
—_EVENTAssigning names to events.
LEFT/RIGHT_SIDE_RESULT_NAME_PREFIXAssigning names to left and right sides
RESULT_NAME_SUFFIXSpecify suffix applied to results
APPEND_COMPONENT_TO_RESULT_NAMEwhether or not to change component name
MERGE_COMPONENTSWhether or not to merge components

Dialog

The command can be edited in a text editor or in a dialog form. To edit in the dialog pop up form either click on the Edit button in the pipeline workshop or double-click on the pipeline command. The dialog is shown below.

gaitsignalstatsdlg.jpg

The dialog box allows you to assign values to the command parameters outlined above.

Notes and Examples

Resulting_Signals

Several of the command parameters affect the signal that is created.

Example1

This group of commands results in a metric signal being created in the SIGNAL_STATS folder that is the same name as /Signal_Names parameter and it contains values related to the X-Component of the signal.

/RESULT_FOLDER=SIGNAL_STATS /APPEND_COMPONENT_TO_RESULT_NAME=FALSE /RESULT_NAME_SUFFIX= /COMPONENT_SEQUENCE=X /MERGE_COMPONENTS=FALSE

Example2

This group of commands results in a metric signal being created in the SIGNAL_STATS folder that appends the string _Stats to the name in the /Signal_Names parameter and it contains values related to the X-Component of the signal.

/RESULT_FOLDER=SIGNAL_STATS /APPEND_COMPONENT_TO_RESULT_NAME=TRUE /RESULT_NAME_SUFFIX=_Stats /COMPONENT_SEQUENCE=X /MERGE_COMPONENTS=FALSE

Example3

This group of commands results in a metric signal being created in the SIGNAL_STATS folder that appends the string “_Stats_X” to the name in the /Signal_Names parameter and it contains values related to the X-Component of the signal.

/RESULT_FOLDER=SIGNAL_STATS /APPEND_COMPONENT_TO_RESULT_NAME=TRUE /RESULT_NAME_SUFFIX=_Stats /COMPONENT_SEQUENCE=X /MERGE_COMPONENTS=FALSE

Example4

This group of commands results in a metric signal being created in the SIGNAL_STATS folder that appends the string “_Stats_X” to the name in the /Signal_Names parameter containing values related to the X-Component of the signal; “_Stats_Y” to the name in the /Signal_Names parameter containing values related to the Y-Component of the signals.;“_Stats_Z” to the name in the /Signal_Names parameter containing values related to the Z-Component of the signals..

/RESULT_FOLDER=SIGNAL_STATS /APPEND_COMPONENT_TO_RESULT_NAME=TRUE /RESULT_NAME_SUFFIX=_Stats /COMPONENT_SEQUENCE=ALL /MERGE_COMPONENTS=FALSE

Example5

This group of commands results in a metric signal being created in the SIGNAL_STATS folder that appends the string “_Stats” to the name in the /Signal_Names parameter containing values related to the X-Component of the signal; The resulting signal contains 3 frames of data. The first row is related to the X-Component, the second row is related to the Y-Component and the third row is related to the Z-Component.

/RESULT_FOLDER=SIGNAL_STATS /APPEND_COMPONENT_TO_RESULT_NAME=FALSE /RESULT_NAME_SUFFIX=_Stats /COMPONENT_SEQUENCE=ALL /MERGE_COMPONENTS=TRUE