Set Pipeline Parameter From Expression
Set_Pipeline_Parameter_From_Expression /PARAMETER_NAME=t_Mass /EXPRESSION=METRIC::PROCESSED::HEIGHT * 4.6 /AS_INTEGER=TRUE ; The pipeline parameter contains the value of the expression.
Getting the syntax correct can be challenging because there can be a conflict between the & as a concatenation parameter in a pipeline parameter and the & as a boolean “and” operator.
For many pipeline commands Visual3D recognizes the conflict and handles the situations in a context specific way.
Visual3D cannot make that distinction and “bad” things happen.
Consider the following which uses string comparisons and a pipeline parameter in the expression:
Set_Pipeline_Parameter_From_Expression /PARAMETER_NAME= MVAL /EXPRESSION=(&::TAG_NAMES& == Utility) * 4.6 /AS_INTEGER=FALSE ; The goal was to set MVAL to 4.6 when the pipeline parameter TAG_NAMES was equal to the string “Utility”;
One solution is to separate the pipeline parameter from the expression.
Set_Pipeline_Parameter
/PARAMETER_NAME=TEMP
/PARAMETER_VALUE=(&::TAG_NAMES& == Utility)*4.6
;
Set_Pipeline_Parameter_From_Expression
/PARAMETER_NAME=t_Mass
/EXPRESSION=::TEMP
/AS_INTEGER=FALSE
;
Another solution, which is even trickier in terms of syntax is:
Set_Pipeline_Parameter_From_Expression /PARAMETER_NAME=SCOTT /EXPRESSION=(“&::TAG_NAMES&”==“ Utility”) ! /AS_INTEGER=TRUE ; This forces Visual3D to recognize the strings as strings and the & is treated correctly.
Get global metrics
Global metrics can be set to a pipeline parameter by setting “GLOBAL” in front of the metric name. More information about expressions can be found here.
Set_Pipeline_Parameter_From_Expression /PARAMETER_NAME=KATIE /EXPRESSION=GLOBAL::METRIC::PROCESSED::MASS /AS_INTEGER=FALSE ;