User Tools

Site Tools


visual3d:documentation:pipeline:signal_commands:replace

Replace

Replace data points in a signal interpolated values. This command uses the same algorithms as the interpolate command but it removes meaningless data in the specified range.

Replace
/Signal_Types= The type of signal to be processed
/Signal_Names= The names of the signals to be processed
/Signal_Folder= The name of the signal folder
/Start_Frame= The first frame in the range of data points.
/End_Frame= The last frame in the range of data points.
/Polynomial_Order=The order of the polynomial used.
/Num_Fit= The number of frames of data before and after the “gap” that are used to calculate the coefficients of the polynomial.

The following example results in replacing frames 60 to 72 of the RFT1 motion capture marker (TARGET) with interpolated values using a third order polynomial interpolated using 6 frames before and 6 frames after the specified range.

Replace /Signal_Types=TARGET /Signal_Names=RFT1 /Signal_Folder=ORIGINAL /Start_Frame=60 /End_Frame=72 /Polynomial_Order=3 /Num_Fit=6 ;

visual3d/documentation/pipeline/signal_commands/replace.txt · Last modified: 2024/07/17 11:46 by sgranger