Revision as of 20:27, 4 September 2020
Inspect3D v2020 09 07
- Normalization:
- Allow user to specify spline (cubic or linear)
- Change default spline from linear to cubic to match Visual3D default normalization
- Don't normalize Metric or P2D items
- Don't plot standard deviation band if there is no standard deviation (i.e. one subject)
- Text Export:
- Export metric items from CMZ
- Export PCA extreme plots (+/- 1 SD and 5/95%)
- Modify header names when exporting signals to standard ASCII (see below):
Row | Group | Subject | "Raw" | "Raw Events" | "Raw Original" | "Raw Events Original" |
---|---|---|---|---|---|---|
File Name | CMO Library Path | CMO Name | C3D Name | C3D Name | C3D Name | C3D Name |
Signal Name | Group_Mean/Std_Dev | Subj_Mean/Std_Dev | SignalName_Frames | EventName | SignalName_Frames | EventName |
Signal Type | P2D | P2D | P2D/Metric | Events | Derived/Metric/P2D | Event_Frames |
Signal Folder | Group Name | |||||
Signal Component | Signal Component(s) |