Downsample Data

From Software Product Documentation
Jump to navigation Jump to search

Downsample all TARGET signals or all ANALOG signals by an integer multiple.

Note: As of February 2017, this is still a hidden and unsupported command

If modifying the ANALOG rate, not that the resulting ANALOG rate must be an integer multiple of the TARGET rate.

Pipeline Command

Downsample_Data
/OLD_FILE_NAME=
/SIGNAL_TYPES=
/NEW_POINT_RATE=
/NEW_ANALOG_RATE=
;

Example: Downsample TARGET

Given a c3d file with a POINT rate of 50 and an ANALOG rate of 200

Downsample the POINT signals to 25

Downsample_Data
/OLD_FILE_NAME=*test.c3d
/SIGNAL_TYPES=TARGET
/NEW_POINT_RATE=25
/NEW_ANALOG_RATE=
;

Example: Downsample ANALOG

Given a c3d file with a POINT rate of 50 and an ANALOG rate of 200

Downsample the ANALOG signals to 100

Downsample_Data
/OLD_FILE_NAME=*test.c3d
/SIGNAL_TYPES=ANALOG
/NEW_POINT_RATE=
/NEW_ANALOG_RATE=100
;
Retrieved from ""