Downsample Data
Jump to navigation
Jump to search
Downsample all TARGET signals or all ANALOG signals by an integer multiple.
Note: As of February 2017, this is still a hidden and unsupported command
If modifying the ANALOG rate, not that the resulting ANALOG rate must be an integer multiple of the TARGET rate.
Pipeline Command
- Downsample_Data
- /OLD_FILE_NAME=
- /SIGNAL_TYPES=
- /NEW_POINT_RATE=
- /NEW_ANALOG_RATE=
- ;
Example: Downsample TARGET
Given a c3d file with a POINT rate of 50 and an ANALOG rate of 200
Downsample the POINT signals to 25
- Downsample_Data
- /OLD_FILE_NAME=*test.c3d
- /SIGNAL_TYPES=TARGET
- /NEW_POINT_RATE=25
- /NEW_ANALOG_RATE=
- ;
Example: Downsample ANALOG
Given a c3d file with a POINT rate of 50 and an ANALOG rate of 200
Downsample the ANALOG signals to 100
- Downsample_Data
- /OLD_FILE_NAME=*test.c3d
- /SIGNAL_TYPES=ANALOG
- /NEW_POINT_RATE=
- /NEW_ANALOG_RATE=100
- ;