FP BASELINES

From Software Product Documentation
Jump to navigation Jump to search

C3D Parameter Force_Platform BASELINES

The FORCE_PLATFORM:ZERO C3D parameter defines the range of frames used to calculate an average baseline value for each ANALOG signal that is then subtracted from every frame. This does not affect the ANALOG signals (as seen in the data tree), this processing takes place when the Force Platform signals are computed.

Instead of using the ZERO parameter, it is possible to specify the BASELINE values for each channel directly.

This parameter was introduced by C-Motion to accommodate Real-time streaming data. For streaming data there is no frame number from which to define a range for the ZERO parameter. This doesn't mean that the ZERO parameter should be ignored.

Retrieved from ""