Metric Signal Values in Sequence

From Software Product Documentation
Jump to navigation Jump to search
Language:  English  • français • italiano • português • español 

Get the values of a signal at a number of frames within an event sequence.

Frames type:
1 - Point Frames
2 - Data Frames
3 - Interpolate

Metric_Signal_Values_In_Sequence
/RESULT_METRIC_NAME=
! /RESULT_METRIC_FOLDER=PROCESSED
/EXPRESSION=
! /PERCENT_LIST=
! /TIME_OFFSET_LIST=
! /FRAME_OFFSET_LIST=
! /USE_FRAMES_TYPE=1
! /SEQUENCE_INSTANCE=0
! /EVENT_SEQUENCE=
! /EXCLUDE_EVENTS=
! /GENERATE_MEAN_AND_STDDEV=TRUE
! /APPEND_TO_EXISTING_VALUES=FALSE
! /RETAIN_NO_DATA_VALUES=TRUE
;



Example

To get the metric value of the left knee angle at 25 percent of the gait cycle:

NOTE: The Metric_Signal_Values_In_Sequence command may be edited through the text editor (left) or the GUI (right).

Metric_Signal_Values_In_Sequence
  /RESULT_METRIC_NAME=LEFT_KNEE_ANGLE_25percent
! /RESULT_METRIC_FOLDER=PROCESSED
  /EXPRESSION=LINK_MODEL_BASED::ORIGINAL::LEFT_KNEE_ANGLE
  /PERCENT_LIST=25
! /TIME_OFFSET_LIST=
  /USE_FRAMES_TYPE=2 
! /SEQUENCE_INSTANCE=0 
  /EVENT_SEQUENCE=LHS+LHS
! /EXCLUDE_EVENTS=
! /GENERATE_MEAN_AND_STDDEV=TRUE 
! /APPEND_TO_EXISTING_VALUES=FALSE 
! /RETAIN_NO_DATA_VALUES=TRUE
; 

caption