Inspect3D Documentation ToolBar
Language: | English • français • italiano • português • español |
---|
Introduction
The tool bar originally appears at the top left hand side of the page. However, its sections can be moved by selecting the set of vertical dots on the left side of the section and dragging it into a new position. If you right click on the tool bar a dropdown menu will appear that will allow you to hide any of the tool bar sections.
Buttons
Workspace Handling
- Clear Workspace: clear all the graphs, queries and library paths
- Load Workspace: open a workspace that you had previously created and saved (includes group definitions and plots)
- The file being loaded must be in the .i3d format and must have been saved in Inspect3D, a text file saved using any other program (such as Visual3D) cannot be loaded.
- Save Workspace As: saves the workspace
- Workspaces may be opened again to continue working where you left off
- Save Workspace: save the current workspace
Show Options
The Show Options button opens the options dialogue. For more information on the options available see the Options page.
Load Library
The Load Library button opens the Library dialogue. For more information on loading libraries see the Load Library page.
Group Definitions
The Group Definitions button is a dropdown with multiple options:
Group Definitions
- Group Definitions: Opens the Group Definition Dialog
- Defines which signals to query from the CMO Library and group different signals together based on different conditions
- Load Group Def & Compute Groups: loads a Q3D file containing group definitions and query the open library
- Save Group Definitions: saves a Q3D file containing all open group definitions
- Clear Group Definitions: clears current group definitions
- Reload Library: re-query the CMO Library (this should be done if you modified the CMO Library in Visual3D)
- Note: Current inclusions/exclusions done in Inspect3D would be overwritten
Layout Options
The layout button allows you to modify the layout of Inspect3D
- Restore Layout: returns the layout of the sections of the screen to the position they were in when the program was started for its current session.
- Save Layout: allows you to save the layout of the screen sections so that they can be reused during another session.
- Load Layout: allows you to open a layout of the screen sections that you had saved during a previous session.
- Restore Default: returns the screen sections to their original positions (as seen on the main documentation page).
Export Results
The Export Results button allows you to export data to a text file.
Reload Library
The Reload Library reloads the library with any changes to the CMO files made outside of Inspect3D. Note any inclusion/exclusions done within Inspect3D would be lost.
Update CMZ Files
The Update CMZs button opens the Update CMZs dialog which allows the you to make changes to the original CMZ files by:
- Creating BAD events or tags to indicate traces that were excluded in Inspect3D
- Update force assignments based on excluded traces
- Creating events or tags to indicate traces that are included in Inspect3D
- Run external pipeline scripts on the active data
- Remove BAD events or tags that were created in the CMZ file by Inspect3D
Show Animation
The Show Animation button opens an animation window that plays the 3D data for all the data the is selected in the graph.
Show Video
The Show Video button opens the video dialogue.
Show Graphs
Pick one graph to display or all graphs:
- Display Graph(s) Graph n,n or Row or Column
- In Options Dialogue -> Plot View Type you can specify the view options:
- Single: Display single graph (Row, Column)
- Row: Display all graphs in that row
- Column: Display all graphs in that column
- In Options Dialogue -> Plot View Type you can specify the view options:
- Show All: returns all of the graphs to the screen
Rescale Graphs
The Rescale Graphs scales the graph so that the graph is fitted to the data that is being graphed.
Highlight All Data
The Highlight All Data option re-highlights all data.
Exclusion Options
- Exclude Highlighted Trace(s): Exclude all highlighted traces from further analysis
- Exclude Highlighted Subject(s): Exclude workspace(s) containing highlighted data from further analysis
- Re-Include All Data: Re-Include any excluded data
PCA Options
The following options allow the user to control the PCA section of Inspect3D.
- Show PCA Graphs: shows/hides the PCA graphs from the main section of the program window
- Number of PCs: the number of primary components that should be calculated
- Use Workspace Mean: use all traces or the the subject means for the PCA calculation
- Run QA Using PCA: Opens the Run QA Using PCA dialog
- Run PCA: instigates the calculation of the primary components
Documentation
The Documentation button produces a drop down menu that allows you to access various Inspect3D wiki pages.
The dropdown menu includes the following links:
-Tutorials. The tutorial button expands into a drop down menu that includes links to specific tutorials, including:
- -Tutorial 1 - Quality Assurance
- -Tutorial 2 - Export Tool
- -Tutorial 3 - Principal Component Analysis
-About
- The About dialogue contains several important pieces of information regarding the Inspect3D program. These include:
- -Version Number
- -Release Date
- -Copyright Information
- -Contact Information (support@c-motion.com)
- -CMLib Version Number
- -License Number
- -The Activation and Deactivation Button